EUR.1 Free-Trade Certificate of Origin Issue

Product family: Exporter Preferential Duty Docs.

Flow: BOM Supplier Declarations → BOM Regional Origin Value Calc → Supplier Long-Term Declar Check → Chamber of Commerce Review → REX / EUR.1 Digital Stamp → EDI Forwarder Consignment Link → Export Customs Brokers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: EUR.1 Free-Trade Certificate of Origin IssueSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. BOM Supplier Declarations → BOM Regional Origin Value Calc (93.0 s) → Supplier Long-Term Declar Check (120 s) → Chamber of Commerce Review (162 s) → REX / EUR.1 Digital Stamp (102 s) → EDI Forwarder Consignment Link (68.0 s) → Export Customs Brokers.SUPPLIERBOM SupplierDeclarationsI1.40 d1BOM RegionalOrigin Value CalcC/T 93.0 sI1.80 d2SupplierLong-Term Declar…C/T 120 sI3.50 d3Chamber ofCommerce ReviewC/T 162 sI0.90 d4REX / EUR.1Digital StampC/T 102 sI0.40 d5EDI ForwarderConsignment LinkC/T 68.0 sI0.30 dCUSTOMERExport CustomsBrokers180 / files

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. BOM Regional Origin Value Calc93.0 s5 min97%91.5%45252 (1.40 d)246
2. Supplier Long-Term Declar Check120 s8 min93%94.0%45324 (1.80 d)183
3. Chamber of Commerce Review162 s12 min85%89.0%36630 (3.50 d)109
4. REX / EUR.1 Digital Stamp102 s4 min96%97.8%18162 (0.90 d)226
5. EDI Forwarder Consignment Link68.0 s2 min99%99.5%1872 (0.40 d)374

Key figures

Takt time
150 s
Lead time
8.32 d
Value-added time
545 s
Process cycle efficiency (PCE)
0.24%
Rolled throughput yield (RTY)
74.5%
Customer demand per day
180 files
Line capacity per day
109 files
Bottleneck
Chamber of Commerce Review

Reading the bottleneck

The bottleneck is "Chamber of Commerce Review": it can process 109 files per day against a demand of 180 files, so it falls short of demand by 39.3%. Once downtime and scrap are counted, its cycle time grows from 162 s to 214 s, against a takt of 150 s. The largest loss at this step is equipment downtime (uptime 85%), about 28.6 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Legal Ops, Contracts, IP & Tenders: Legal Ops, Contracts, IP & Tenders