Annual External Gray-Box Application Pen-Test

Product family: OWASP Top-10 Remediation.

Flow: CREST Ethical Hackers → Scope Lock & Test Credentials → 2-Week Manual Exploit Hunt → Critical/High Triage Fix Sprint → Independent Retest Verification → Clean Attestation Letter Print → Enterprise Compliance

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Annual External Gray-Box Application Pen-TestSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. CREST Ethical Hackers → Scope Lock & Test Credentials (1,957 s) → 2-Week Manual Exploit Hunt (3,611 s) → Critical/High Triage Fix Sprint (2,768 s) → Independent Retest Verification (2,430 s) → Clean Attestation Letter Print (1,688 s) → Enterprise Compliance.SUPPLIERCREST EthicalHackersI0.75 d1Scope Lock & TestCredentialsC/T 1,957 sI2.75 d22-Week ManualExploit HuntC/T 3,611 sI1.63 d3Critical/HighTriage Fix SprintC/T 2,768 sI0.88 d4IndependentRetest…C/T 2,430 sI0.50 d5Clean AttestationLetter PrintC/T 1,688 sI0.25 dCUSTOMEREnterpriseCompliance8 / cases

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Scope Lock & Test Credentials1,957 s5 min97%96.5%26 (0.75 d)12
2. 2-Week Manual Exploit Hunt3,611 s15 min86%89.5%222 (2.75 d)5
3. Critical/High Triage Fix Sprint2,768 s10 min93%95.8%213 (1.63 d)8
4. Independent Retest Verification2,430 s6 min95%97.6%17 (0.88 d)10
5. Clean Attestation Letter Print1,688 s3 min98%99.1%14 (0.50 d)15

Key figures

Takt time
3,375 s
Lead time
7.21 d
Value-added time
12,454 s
Process cycle efficiency (PCE)
6.4%
Rolled throughput yield (RTY)
80.0%
Customer demand per day
8 cases
Line capacity per day
5 cases
Bottleneck
2-Week Manual Exploit Hunt

Reading the bottleneck

The bottleneck is "2-Week Manual Exploit Hunt": it can process 5 cases per day against a demand of 8 cases, so it falls short of demand by 37.7%. Once downtime and scrap are counted, its cycle time grows from 3,611 s to 4,691 s, against a takt of 3,375 s. The largest loss at this step is equipment downtime (uptime 86%), about 588 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of SaaS Onboarding, RevOps & CX Ops: SaaS Onboarding, RevOps & CX Ops