B2B Heavy Machinery & Truck Leasing Underwrite

Product family: Residual-Value Asset Leases.

Flow: Asset Valuators & Registries → Equipment Serial Spec Intake → Residual Value Curve Score → Credit & Collateral Committee → Master Lease E-Sign & Insur → Supplier Invoice Direct Pay → Transport & Mfg Lessees

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: B2B Heavy Machinery & Truck Leasing UnderwriteSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Asset Valuators & Registries → Equipment Serial Spec Intake (314 s) → Residual Value Curve Score (383 s) → Credit & Collateral Committee (525 s) → Master Lease E-Sign & Insur (304 s) → Supplier Invoice Direct Pay (206 s) → Transport & Mfg Lessees.SUPPLIERAsset Valuators& RegistriesI1.80 d1Equipment SerialSpec IntakeC/T 314 sI1.60 d2Residual ValueCurve ScoreC/T 383 sI3.20 d3Credit &Collateral…C/T 525 sI1.00 d4Master LeaseE-Sign & InsurC/T 304 sI0.51 d5Supplier InvoiceDirect PayC/T 206 sI0.51 dCUSTOMERTransport & MfgLessees55 / files

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Equipment Serial Spec Intake314 s5 min96%86.0%1499 (1.80 d)68
2. Residual Value Curve Score383 s8 min94%91.5%1488 (1.60 d)56
3. Credit & Collateral Committee525 s12 min86%88.0%11176 (3.20 d)34
4. Master Lease E-Sign & Insur304 s5 min97%96.5%655 (1.00 d)75
5. Supplier Invoice Direct Pay206 s2 min99%99.4%628 (0.51 d)124

Key figures

Takt time
491 s
Lead time
8.68 d
Value-added time
1,732 s
Process cycle efficiency (PCE)
0.74%
Rolled throughput yield (RTY)
66.4%
Customer demand per day
55 files
Line capacity per day
34 files
Bottleneck
Credit & Collateral Committee

Reading the bottleneck

The bottleneck is "Credit & Collateral Committee": it can process 34 files per day against a demand of 55 files, so it falls short of demand by 38.7%. Once downtime and scrap are counted, its cycle time grows from 525 s to 694 s, against a takt of 491 s. The largest loss at this step is equipment downtime (uptime 86%), about 85.5 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Banking, Loans & Credit Underwriting: Banking, Loans & Credit Underwriting