Green Energy Solar & Wind Project Finance

Product family: ESG Non-Recourse PPA Debt.

Flow: Independent Technical Advisors → P50/P90 Yield & PPA Audit → Independent Engineer Tech Due → Green Taxonomy & Credit Desk → Security Trustee Financing Docs → Construction Milestone Tranche → Utility IPP Developers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Green Energy Solar & Wind Project FinanceSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Independent Technical Advisors → P50/P90 Yield & PPA Audit (2,880 s) → Independent Engineer Tech Due (3,510 s) → Green Taxonomy & Credit Desk (4,815 s) → Security Trustee Financing Docs (2,790 s) → Construction Milestone Tranche (1,890 s) → Utility IPP Developers.SUPPLIERIndependentTechnicalAdvisorsI1.83 d1P50/P90 Yield &PPA AuditC/T 2,880 sI1.67 d2IndependentEngineer Tech DueC/T 3,510 sI3.17 d3Green Taxonomy &Credit DeskC/T 4,815 sI1.00 d4Security TrusteeFinancing DocsC/T 2,790 sI0.50 d5ConstructionMilestone TrancheC/T 1,890 sI0.50 dCUSTOMERUtility IPPDevelopers6 / files

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. P50/P90 Yield & PPA Audit2,880 s5 min96%86.0%211 (1.83 d)7
2. Independent Engineer Tech Due3,510 s8 min94%91.5%210 (1.67 d)6
3. Green Taxonomy & Credit Desk4,815 s12 min86%88.0%119 (3.17 d)4
4. Security Trustee Financing Docs2,790 s5 min97%96.5%16 (1.00 d)9
5. Construction Milestone Tranche1,890 s2 min99%99.4%13 (0.50 d)14

Key figures

Takt time
4,500 s
Lead time
9.25 d
Value-added time
15,885 s
Process cycle efficiency (PCE)
6.4%
Rolled throughput yield (RTY)
66.4%
Customer demand per day
6 files
Line capacity per day
4 files
Bottleneck
Green Taxonomy & Credit Desk

Reading the bottleneck

The bottleneck is "Green Taxonomy & Credit Desk": it can process 4 files per day against a demand of 6 files, so it falls short of demand by 31.2%. Once downtime and scrap are counted, its cycle time grows from 4,815 s to 6,362 s, against a takt of 4,500 s. The largest loss at this step is equipment downtime (uptime 86%), about 784 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Banking, Loans & Credit Underwriting: Banking, Loans & Credit Underwriting