Automated Multi-Jurisdiction EU VAT & SAF-T Return

Product family: Statutory Indirect Tax Close.

Flow: ERP Sales & Purchase Ledgers → Ledger Tax Data Extraction → Missing Tax-ID Anomaly Scan → Cross-Border Intrastat Recon → Tax Director Statutory Review → XML Direct E-Filing & Payment → Tax Authorities Portals

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Automated Multi-Jurisdiction EU VAT & SAF-T ReturnSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. ERP Sales & Purchase Ledgers → Ledger Tax Data Extraction (743 s) → Missing Tax-ID Anomaly Scan (878 s) → Cross-Border Intrastat Recon (1,204 s) → Tax Director Statutory Review (720 s) → XML Direct E-Filing & Payment (563 s) → Tax Authorities Portals.SUPPLIERERP Sales &PurchaseLedgersI1.42 d1Ledger Tax DataExtractionC/T 743 sI1.50 d2Missing Tax-IDAnomaly ScanC/T 878 sI2.92 d3Cross-BorderIntrastat ReconC/T 1,204 sI0.92 d4Tax DirectorStatutory ReviewC/T 720 sI0.50 d5XML DirectE-Filing &…C/T 563 sI0.50 dCUSTOMERTax AuthoritiesPortals24 / files

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Ledger Tax Data Extraction743 s2 min96%89.5%634 (1.42 d)31
2. Missing Tax-ID Anomaly Scan878 s2 min95%93.8%636 (1.50 d)27
3. Cross-Border Intrastat Recon1,204 s8 min86%89.0%570 (2.92 d)16
4. Tax Director Statutory Review720 s3 min97%98.4%522 (0.92 d)35
5. XML Direct E-Filing & Payment563 s2 min99%99.1%412 (0.50 d)46

Key figures

Takt time
1,125 s
Lead time
7.90 d
Value-added time
4,108 s
Process cycle efficiency (PCE)
1.9%
Rolled throughput yield (RTY)
72.9%
Customer demand per day
24 files
Line capacity per day
16 files
Bottleneck
Cross-Border Intrastat Recon

Reading the bottleneck

The bottleneck is "Cross-Border Intrastat Recon": it can process 16 files per day against a demand of 24 files, so it falls short of demand by 34.6%. Once downtime and scrap are counted, its cycle time grows from 1,204 s to 1,573 s, against a takt of 1,125 s. The largest loss at this step is equipment downtime (uptime 86%), about 196 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Order-to-Cash, P2P & Shared Services: Order-to-Cash, P2P & Shared Services