Mid-Market Commercial Property & Liability Quote

Product family: Multi-Peril Policy Binding.

Flow: Broker Submissions & Credit Reports → Broker Email PDF Parse → Catastrophe GIS Flood/Quake → Senior Underwriter Price Blend → Quote Letter Issuance → Policy Bind & Cert Generation → Commercial Insurance Brokers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Mid-Market Commercial Property & Liability QuoteSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Broker Submissions & Credit Reports → Broker Email PDF Parse (282 s) → Catastrophe GIS Flood/Quake (324 s) → Senior Underwriter Price Blend (449 s) → Quote Letter Issuance (282 s) → Policy Bind & Cert Generation (187 s) → Commercial Insurance Brokers.SUPPLIERBrokerSubmissions &Credit ReportsI1.40 d1Broker Email PDFParseC/T 282 sI1.80 d2Catastrophe GISFlood/QuakeC/T 324 sI3.40 d3SeniorUnderwriter Pric…C/T 449 sI0.80 d4Quote LetterIssuanceC/T 282 sI0.40 d5Policy Bind &Cert GenerationC/T 187 sI0.40 dCUSTOMERCommercialInsurance…65 / files

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Broker Email PDF Parse282 s3 min97%88.0%1391 (1.40 d)79
2. Catastrophe GIS Flood/Quake324 s5 min94%93.5%16117 (1.80 d)70
3. Senior Underwriter Price Blend449 s10 min86%89.0%16221 (3.40 d)42
4. Quote Letter Issuance282 s4 min96%97.4%752 (0.80 d)82
5. Policy Bind & Cert Generation187 s2 min99%99.1%726 (0.40 d)136

Key figures

Takt time
415 s
Lead time
8.26 d
Value-added time
1,524 s
Process cycle efficiency (PCE)
0.68%
Rolled throughput yield (RTY)
70.7%
Customer demand per day
65 files
Line capacity per day
42 files
Bottleneck
Senior Underwriter Price Blend

Reading the bottleneck

The bottleneck is "Senior Underwriter Price Blend": it can process 42 files per day against a demand of 65 files, so it falls short of demand by 35.6%. Once downtime and scrap are counted, its cycle time grows from 449 s to 587 s, against a takt of 415 s. The largest loss at this step is equipment downtime (uptime 86%), about 73.1 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Insurance Claims & Policy Ops: Insurance Claims & Policy Ops