Construction Performance & Bid Surety Bond Desk

Product family: 24-Hr Contractor Bond Issue.

Flow: Audited Contractor Financials → Project Specs & WIP Balance In → Liquidity & Backlog Underwrite → Attorney-in-Fact Risk Sign → Digital Seal Bond Print → Project Obligee Registration → General Civil Contractors

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Construction Performance & Bid Surety Bond DeskSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Audited Contractor Financials → Project Specs & WIP Balance In (437 s) → Liquidity & Backlog Underwrite (501 s) → Attorney-in-Fact Risk Sign (694 s) → Digital Seal Bond Print (437 s) → Project Obligee Registration (289 s) → General Civil Contractors.SUPPLIERAuditedContractorFinancialsI1.40 d1Project Specs &WIP Balance InC/T 437 sI1.81 d2Liquidity &Backlog…C/T 501 sI3.40 d3Attorney-in-FactRisk SignC/T 694 sI0.81 d4Digital Seal BondPrintC/T 437 sI0.40 d5Project ObligeeRegistrationC/T 289 sI0.40 dCUSTOMERGeneral CivilContractors42 / files

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Project Specs & WIP Balance In437 s3 min97%88.0%859 (1.40 d)51
2. Liquidity & Backlog Underwrite501 s5 min94%93.5%1176 (1.81 d)45
3. Attorney-in-Fact Risk Sign694 s10 min86%89.0%11143 (3.40 d)27
4. Digital Seal Bond Print437 s4 min96%97.4%434 (0.81 d)52
5. Project Obligee Registration289 s2 min99%99.1%417 (0.40 d)87

Key figures

Takt time
643 s
Lead time
8.33 d
Value-added time
2,358 s
Process cycle efficiency (PCE)
1.0%
Rolled throughput yield (RTY)
70.7%
Customer demand per day
42 files
Line capacity per day
27 files
Bottleneck
Attorney-in-Fact Risk Sign

Reading the bottleneck

The bottleneck is "Attorney-in-Fact Risk Sign": it can process 27 files per day against a demand of 42 files, so it falls short of demand by 35.1%. Once downtime and scrap are counted, its cycle time grows from 694 s to 907 s, against a takt of 643 s. The largest loss at this step is equipment downtime (uptime 86%), about 113 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Insurance Claims & Policy Ops: Insurance Claims & Policy Ops