Twice-Daily Pharmacy Wholesaler Tote Sorting

Product family: Temperature-Logged Green Totes.

Flow: 120 Pharma Manufacturers → Pallet Putaway & Batch Lot → A-Frame Auto Dispense Drop → Narcotic Cage & Cold Pick → FMD Aggregation Scan Gate → Van Route Sequenced Load → Community Pharmacies

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Twice-Daily Pharmacy Wholesaler Tote SortingSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. 120 Pharma Manufacturers → Pallet Putaway & Batch Lot (5.8 s) → A-Frame Auto Dispense Drop (7.5 s) → Narcotic Cage & Cold Pick (10.3 s) → FMD Aggregation Scan Gate (8.1 s) → Van Route Sequenced Load (5.0 s) → Community Pharmacies.SUPPLIER120 PharmaManufacturersI1.20 d1Pallet Putaway &Batch LotC/T 5.8 sI1.60 d2A-Frame AutoDispense DropC/T 7.5 sI1.10 d3Narcotic Cage &Cold PickC/T 10.3 sI0.70 d4FMD AggregationScan GateC/T 8.1 sI0.40 d5Van RouteSequenced LoadC/T 5.0 sI0.50 dCUSTOMERCommunityPharmacies5,600 / orders

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Pallet Putaway & Batch Lot5.8 s15 min95%98.8%2,8006,720 (1.20 d)8,447
2. A-Frame Auto Dispense Drop7.5 s10 min94%99.1%2,2408,960 (1.60 d)6,521
3. Narcotic Cage & Cold Pick10.3 s18 min89%96.9%1,6806,160 (1.10 d)4,220
4. FMD Aggregation Scan Gate8.1 s8 min93%98.4%1,1203,920 (0.70 d)5,830
5. Van Route Sequenced Load5.0 s12 min97%99.5%2,2402,240 (0.40 d)10,076

Key figures

Takt time
9.6 s
Lead time
5.50 d
Value-added time
36.7 s
Process cycle efficiency (PCE)
0.012%
Rolled throughput yield (RTY)
92.9%
Customer demand per day
5,600 orders
Line capacity per day
4,220 orders
Bottleneck
Narcotic Cage & Cold Pick

Reading the bottleneck

The bottleneck is "Narcotic Cage & Cold Pick": it can process 4,220 orders per day against a demand of 5,600 orders, so it falls short of demand by 24.6%. Once downtime and scrap are counted, its cycle time grows from 10.3 s to 11.9 s, against a takt of 9.6 s. The largest loss at this step is equipment downtime (uptime 89%), about 1.3 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of E-Commerce Fulfillment & 3PL Hubs: E-Commerce Fulfillment & 3PL Hubs