Flammable Perfume & Aerosol DG E-Commerce Cell

Product family: ADR LQ Limited-Quantity Pack.

Flow: Luxury Fragrance Houses → ATEX Ventilated Cage Receive → Spill-Tray Sprinkler Racking → Grounded Anti-Static Pick → UN LQ Diamond Box Cushion → Dedicated Ground DG Carrier → Online Perfume Buyers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Flammable Perfume & Aerosol DG E-Commerce CellSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Luxury Fragrance Houses → ATEX Ventilated Cage Receive (20.3 s) → Spill-Tray Sprinkler Racking (26.3 s) → Grounded Anti-Static Pick (36.1 s) → UN LQ Diamond Box Cushion (28.3 s) → Dedicated Ground DG Carrier (17.6 s) → Online Perfume Buyers.SUPPLIERLuxuryFragranceHousesI1.20 d1ATEX VentilatedCage ReceiveC/T 20.3 sI1.60 d2Spill-TraySprinkler RackingC/T 26.3 sI1.10 d3GroundedAnti-Static PickC/T 36.1 sI0.70 d4UN LQ Diamond BoxCushionC/T 28.3 sI0.40 d5Dedicated GroundDG CarrierC/T 17.6 sI0.50 dCUSTOMEROnline PerfumeBuyers1,600 / orders

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. ATEX Ventilated Cage Receive20.3 s15 min95%98.8%8001,920 (1.20 d)2,414
2. Spill-Tray Sprinkler Racking26.3 s10 min94%99.1%6402,560 (1.60 d)1,860
3. Grounded Anti-Static Pick36.1 s18 min89%96.9%4801,760 (1.10 d)1,204
4. UN LQ Diamond Box Cushion28.3 s8 min93%98.4%3201,120 (0.70 d)1,669
5. Dedicated Ground DG Carrier17.6 s12 min97%99.5%640640 (0.40 d)2,863

Key figures

Takt time
33.8 s
Lead time
5.50 d
Value-added time
129 s
Process cycle efficiency (PCE)
0.043%
Rolled throughput yield (RTY)
92.9%
Customer demand per day
1,600 orders
Line capacity per day
1,204 orders
Bottleneck
Grounded Anti-Static Pick

Reading the bottleneck

The bottleneck is "Grounded Anti-Static Pick": it can process 1,204 orders per day against a demand of 1,600 orders, so it falls short of demand by 24.7%. Once downtime and scrap are counted, its cycle time grows from 36.1 s to 41.9 s, against a takt of 33.8 s. The largest loss at this step is equipment downtime (uptime 89%), about 4.5 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of E-Commerce Fulfillment & 3PL Hubs: E-Commerce Fulfillment & 3PL Hubs