Phishing Inbox Compromise Account Containment

Product family: 10-Min Account Lockdown.

Flow: Email Gateway & User Reports → Phishing Link URL Sandbox → Kill Active Session & Token → Mailbox Forwarding Rule Scrub → User MFA Hardware Key Reset → Retroactive Tenant Mail Purge → Global Workforce

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Phishing Inbox Compromise Account ContainmentSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Email Gateway & User Reports → Phishing Link URL Sandbox (243 s) → Kill Active Session & Token (360 s) → Mailbox Forwarding Rule Scrub (482 s) → User MFA Hardware Key Reset (324 s) → Retroactive Tenant Mail Purge (216 s) → Global Workforce.SUPPLIEREmail Gateway &User ReportsI0.60 d1Phishing Link URLSandboxC/T 243 sI1.40 d2Kill ActiveSession & TokenC/T 360 sI2.20 d3MailboxForwarding Rule…C/T 482 sI0.90 d4User MFA HardwareKey ResetC/T 324 sI0.40 d5RetroactiveTenant Mail PurgeC/T 216 sI0.40 dCUSTOMERGlobalWorkforce180 / tickets

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Phishing Link URL Sandbox243 s2 min98%91.5%18108 (0.60 d)294
2. Kill Active Session & Token360 s4 min94%93.0%36252 (1.40 d)194
3. Mailbox Forwarding Rule Scrub482 s10 min86%90.0%54396 (2.20 d)127
4. User MFA Hardware Key Reset324 s6 min95%96.5%36162 (0.90 d)224
5. Retroactive Tenant Mail Purge216 s2 min99%98.5%1872 (0.40 d)360

Key figures

Takt time
450 s
Lead time
5.92 d
Value-added time
1,625 s
Process cycle efficiency (PCE)
0.34%
Rolled throughput yield (RTY)
72.8%
Customer demand per day
180 tickets
Line capacity per day
127 tickets
Bottleneck
Mailbox Forwarding Rule Scrub

Reading the bottleneck

The bottleneck is "Mailbox Forwarding Rule Scrub": it can process 127 tickets per day against a demand of 180 tickets, so it falls short of demand by 29.5%. Once downtime and scrap are counted, its cycle time grows from 482 s to 623 s, against a takt of 450 s. The largest loss at this step is equipment downtime (uptime 86%), about 78.5 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of ITSM Service Desk, SecOps & Cloud Ops: ITSM Service Desk, SecOps & Cloud Ops