Multi-Site Factory RF Wi-Fi 6E Outage Escalate

Product family: Zero-Deadzone AGV Roaming Fix.

Flow: AGV Telemetry & AP Alerts → AP Controller Drop Detection → Packet Capture Roaming Trace → Channel Co-Interference Tune → PoE Switch / AP Field Swap → AGV Roam Stress Verification → Automated Plant Floor Ops

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Multi-Site Factory RF Wi-Fi 6E Outage EscalateSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. AGV Telemetry & AP Alerts → AP Controller Drop Detection (530 s) → Packet Capture Roaming Trace (785 s) → Channel Co-Interference Tune (1,051 s) → PoE Switch / AP Field Swap (707 s) → AGV Roam Stress Verification (471 s) → Automated Plant Floor Ops.SUPPLIERAGV Telemetry &AP AlertsI0.60 d1AP ControllerDrop DetectionC/T 530 sI1.40 d2Packet CaptureRoaming TraceC/T 785 sI2.20 d3ChannelCo-Interference…C/T 1,051 sI0.91 d4PoE Switch / APField SwapC/T 707 sI0.40 d5AGV Roam StressVerificationC/T 471 sI0.40 dCUSTOMERAutomated PlantFloor Ops55 / tickets

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. AP Controller Drop Detection530 s2 min98%91.5%633 (0.60 d)90
2. Packet Capture Roaming Trace785 s4 min94%93.0%1177 (1.40 d)59
3. Channel Co-Interference Tune1,051 s10 min86%90.0%17121 (2.20 d)38
4. PoE Switch / AP Field Swap707 s6 min95%96.5%1150 (0.91 d)68
5. AGV Roam Stress Verification471 s2 min99%98.5%622 (0.40 d)110

Key figures

Takt time
982 s
Lead time
5.97 d
Value-added time
3,544 s
Process cycle efficiency (PCE)
1.1%
Rolled throughput yield (RTY)
72.8%
Customer demand per day
55 tickets
Line capacity per day
38 tickets
Bottleneck
Channel Co-Interference Tune

Reading the bottleneck

The bottleneck is "Channel Co-Interference Tune": it can process 38 tickets per day against a demand of 55 tickets, so it falls short of demand by 30.3%. Once downtime and scrap are counted, its cycle time grows from 1,051 s to 1,358 s, against a takt of 982 s. The largest loss at this step is equipment downtime (uptime 86%), about 171 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of ITSM Service Desk, SecOps & Cloud Ops: ITSM Service Desk, SecOps & Cloud Ops