24/7 Managed Cyber SOC Tier-1/2 Alert Containment

Product family: Zero-Dwell EDR Response.

Flow: SIEM, Firewall & EDR → SIEM Enrichment Auto-Parse → Tier-1 Benigner / True triage → Tier-2 Threat Hunt & Reverse → Host Network Quarantine Run → Post-Incident IOC Rule Push → Enterprise CISO Fleet

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: 24/7 Managed Cyber SOC Tier-1/2 Alert ContainmentSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. SIEM, Firewall & EDR → SIEM Enrichment Auto-Parse (104 s) → Tier-1 Benigner / True triage (154 s) → Tier-2 Threat Hunt & Reverse (206 s) → Host Network Quarantine Run (139 s) → Post-Incident IOC Rule Push (93.0 s) → Enterprise CISO Fleet.SUPPLIERSIEM, Firewall& EDRI0.60 d1SIEM EnrichmentAuto-ParseC/T 104 sI1.40 d2Tier-1 Benigner /True triageC/T 154 sI2.20 d3Tier-2 ThreatHunt & ReverseC/T 206 sI0.90 d4Host NetworkQuarantine RunC/T 139 sI0.40 d5Post-Incident IOCRule PushC/T 93.0 sI0.40 dCUSTOMEREnterprise CISOFleet420 / tickets

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. SIEM Enrichment Auto-Parse104 s2 min98%91.5%42252 (0.60 d)688
2. Tier-1 Benigner / True triage154 s4 min94%93.0%84588 (1.40 d)453
3. Tier-2 Threat Hunt & Reverse206 s10 min86%90.0%126924 (2.20 d)297
4. Host Network Quarantine Run139 s6 min95%96.5%84378 (0.90 d)522
5. Post-Incident IOC Rule Push93.0 s2 min99%98.5%42168 (0.40 d)837

Key figures

Takt time
193 s
Lead time
5.91 d
Value-added time
696 s
Process cycle efficiency (PCE)
0.15%
Rolled throughput yield (RTY)
72.8%
Customer demand per day
420 tickets
Line capacity per day
297 tickets
Bottleneck
Tier-2 Threat Hunt & Reverse

Reading the bottleneck

The bottleneck is "Tier-2 Threat Hunt & Reverse": it can process 297 tickets per day against a demand of 420 tickets, so it falls short of demand by 29.3%. Once downtime and scrap are counted, its cycle time grows from 206 s to 266 s, against a takt of 193 s. The largest loss at this step is equipment downtime (uptime 86%), about 33.5 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of ITSM Service Desk, SecOps & Cloud Ops: ITSM Service Desk, SecOps & Cloud Ops