Zero-Trust Privileged Access Request & Review

Product family: JIT Production DB Access.

Flow: Employee Role Requests → Self-Service Catalog Request → SOX Segregation-of-Duties Check → Resource Owner Approval Wait → Auto-Provision Time-Bound Role → Expiry Auto-Revoke Audit Log → Audit & Engineering Users

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Zero-Trust Privileged Access Request & ReviewSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Employee Role Requests → Self-Service Catalog Request (112 s) → SOX Segregation-of-Duties Check (166 s) → Resource Owner Approval Wait (222 s) → Auto-Provision Time-Bound Role (150 s) → Expiry Auto-Revoke Audit Log (100 s) → Audit & Engineering Users.SUPPLIEREmployee RoleRequestsI0.60 d1Self-ServiceCatalog RequestC/T 112 sI1.40 d2SOXSegregation-of-D…C/T 166 sI2.20 d3Resource OwnerApproval WaitC/T 222 sI0.90 d4Auto-ProvisionTime-Bound RoleC/T 150 sI0.40 d5ExpiryAuto-Revoke Audi…C/T 100 sI0.40 dCUSTOMERAudit &Engineering…260 / tickets

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Self-Service Catalog Request112 s2 min98%91.5%26156 (0.60 d)423
2. SOX Segregation-of-Duties Check166 s4 min94%93.0%52364 (1.40 d)278
3. Resource Owner Approval Wait222 s10 min86%90.0%78572 (2.20 d)181
4. Auto-Provision Time-Bound Role150 s6 min95%96.5%52234 (0.90 d)319
5. Expiry Auto-Revoke Audit Log100 s2 min99%98.5%26104 (0.40 d)515

Key figures

Takt time
208 s
Lead time
5.91 d
Value-added time
750 s
Process cycle efficiency (PCE)
0.23%
Rolled throughput yield (RTY)
72.8%
Customer demand per day
260 tickets
Line capacity per day
181 tickets
Bottleneck
Resource Owner Approval Wait

Reading the bottleneck

The bottleneck is "Resource Owner Approval Wait": it can process 181 tickets per day against a demand of 260 tickets, so it falls short of demand by 30.3%. Once downtime and scrap are counted, its cycle time grows from 222 s to 287 s, against a takt of 208 s. The largest loss at this step is equipment downtime (uptime 86%), about 36.1 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of ITSM Service Desk, SecOps & Cloud Ops: ITSM Service Desk, SecOps & Cloud Ops