Data Center Legacy Server Decommission & Wipe

Product family: Power-Saving Legacy Exit.

Flow: CMDB Aging Server List → App Owner Migration Confirm → Soft Shutdown & 14-Day Scream → Cables Unpatch & Rail Pull → NIST Crypto Disk Shredding → CMDB Retire & Power Reclaim → Facility Power Budget

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Data Center Legacy Server Decommission & WipeSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. CMDB Aging Server List → App Owner Migration Confirm (521 s) → Soft Shutdown & 14-Day Scream (771 s) → Cables Unpatch & Rail Pull (1,032 s) → NIST Crypto Disk Shredding (694 s) → CMDB Retire & Power Reclaim (463 s) → Facility Power Budget.SUPPLIERCMDB AgingServer ListI0.61 d1App OwnerMigration ConfirmC/T 521 sI1.39 d2Soft Shutdown &14-Day ScreamC/T 771 sI2.21 d3Cables Unpatch &Rail PullC/T 1,032 sI0.89 d4NIST Crypto DiskShreddingC/T 694 sI0.39 d5CMDB Retire &Power ReclaimC/T 463 sI0.39 dCUSTOMERFacility PowerBudget28 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. App Owner Migration Confirm521 s2 min98%91.5%317 (0.61 d)45
2. Soft Shutdown & 14-Day Scream771 s4 min94%93.0%639 (1.39 d)29
3. Cables Unpatch & Rail Pull1,032 s10 min86%90.0%862 (2.21 d)19
4. NIST Crypto Disk Shredding694 s6 min95%96.5%625 (0.89 d)33
5. CMDB Retire & Power Reclaim463 s2 min99%98.5%311 (0.39 d)55

Key figures

Takt time
964 s
Lead time
6.02 d
Value-added time
3,481 s
Process cycle efficiency (PCE)
2.1%
Rolled throughput yield (RTY)
72.8%
Customer demand per day
28 units
Line capacity per day
19 units
Bottleneck
Cables Unpatch & Rail Pull

Reading the bottleneck

The bottleneck is "Cables Unpatch & Rail Pull": it can process 19 units per day against a demand of 28 units, so it falls short of demand by 33.3%. Once downtime and scrap are counted, its cycle time grows from 1,032 s to 1,333 s, against a takt of 964 s. The largest loss at this step is equipment downtime (uptime 86%), about 168 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.