University Spin-Out IP Licensing & Startup Launch

Product family: Lab Discovery to Seed Company.

Flow: Faculty Biotech/AI Labs → Invention Commercial Eval → Patent Claim & Market Fit → Exclusive License Redline → Conflict-of-Interest Senate → Spin-Out Equity Execution → Venture Funds & Corporates

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: University Spin-Out IP Licensing & Startup LaunchSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Faculty Biotech/AI Labs → Invention Commercial Eval (2,880 s) → Patent Claim & Market Fit (3,420 s) → Exclusive License Redline (4,860 s) → Conflict-of-Interest Senate (3,150 s) → Spin-Out Equity Execution (2,160 s) → Venture Funds & Corporates.SUPPLIERFacultyBiotech/AI LabsI1.33 d1InventionCommercial EvalC/T 2,880 sI1.83 d2Patent Claim &Market FitC/T 3,420 sI3.83 d3Exclusive LicenseRedlineC/T 4,860 sI0.83 d4Conflict-of-InterestSenateC/T 3,150 sI0.33 d5Spin-Out EquityExecutionC/T 2,160 sI0.33 dCUSTOMERVenture Funds &Corporates6 / cases

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Invention Commercial Eval2,880 s5 min96%91.5%28 (1.33 d)8
2. Patent Claim & Market Fit3,420 s8 min94%93.8%211 (1.83 d)7
3. Exclusive License Redline4,860 s15 min85%88.5%123 (3.83 d)4
4. Conflict-of-Interest Senate3,150 s5 min96%97.6%15 (0.83 d)8
5. Spin-Out Equity Execution2,160 s2 min99%99.4%12 (0.33 d)12

Key figures

Takt time
4,500 s
Lead time
9.11 d
Value-added time
16,470 s
Process cycle efficiency (PCE)
6.7%
Rolled throughput yield (RTY)
73.7%
Customer demand per day
6 cases
Line capacity per day
4 cases
Bottleneck
Exclusive License Redline

Reading the bottleneck

The bottleneck is "Exclusive License Redline": it can process 4 cases per day against a demand of 6 cases, so it falls short of demand by 32.7%. Once downtime and scrap are counted, its cycle time grows from 4,860 s to 6,461 s, against a takt of 4,500 s. The largest loss at this step is changeovers (15 min every 1 units), about 900 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Higher Education, Research & Publishing: Higher Education, Research & Publishing