University Wet Chemistry Lab Annual Biosafety Audit

Product family: BSL-2 Fume Hood Compliance.

Flow: Chemical Inventory Trackers → Chemical Inventory Waste Check → Fume-Hood Face Velocity Test → PI Staff Training Expiry Check → 30-Day Violation Remediation → Clear Bio-Permit Door Sticker → Campus EHS Office

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: University Wet Chemistry Lab Annual Biosafety AuditSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Chemical Inventory Trackers → Chemical Inventory Waste Check (720 s) → Fume-Hood Face Velocity Test (855 s) → PI Staff Training Expiry Check (1,215 s) → 30-Day Violation Remediation (788 s) → Clear Bio-Permit Door Sticker (540 s) → Campus EHS Office.SUPPLIERChemicalInventoryTrackersI1.42 d1ChemicalInventory Waste…C/T 720 sI1.79 d2Fume-Hood FaceVelocity TestC/T 855 sI3.79 d3PI Staff TrainingExpiry CheckC/T 1,215 sI0.92 d430-Day ViolationRemediationC/T 788 sI0.42 d5Clear Bio-PermitDoor StickerC/T 540 sI0.42 dCUSTOMERCampus EHSOffice24 / rooms

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Chemical Inventory Waste Check720 s5 min96%91.5%634 (1.42 d)31
2. Fume-Hood Face Velocity Test855 s8 min94%93.8%643 (1.79 d)26
3. PI Staff Training Expiry Check1,215 s15 min85%88.5%591 (3.79 d)14
4. 30-Day Violation Remediation788 s5 min96%97.6%422 (0.92 d)30
5. Clear Bio-Permit Door Sticker540 s2 min99%99.4%210 (0.42 d)47

Key figures

Takt time
1,125 s
Lead time
8.90 d
Value-added time
4,118 s
Process cycle efficiency (PCE)
1.7%
Rolled throughput yield (RTY)
73.7%
Customer demand per day
24 rooms
Line capacity per day
14 rooms
Bottleneck
PI Staff Training Expiry Check

Reading the bottleneck

The bottleneck is "PI Staff Training Expiry Check": it can process 14 rooms per day against a demand of 24 rooms, so it falls short of demand by 41.5%. Once downtime and scrap are counted, its cycle time grows from 1,215 s to 1,615 s, against a takt of 1,125 s. The largest loss at this step is equipment downtime (uptime 85%), about 214 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Higher Education, Research & Publishing: Higher Education, Research & Publishing