National Science Research Grant Peer-Review

Product family: Multi-Panel Funding Decision.

Flow: Principal Investigators → Budget & Ethics Compliance Check → 3-Peer External Reviewer Match → Panel Scoring & Tie-Break → Award Contract & Sub-Awards → Tranche #1 Lab Grant Release → University Labs & PIs

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: National Science Research Grant Peer-ReviewSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Principal Investigators → Budget & Ethics Compliance Check (617 s) → 3-Peer External Reviewer Match (733 s) → Panel Scoring & Tie-Break (1,041 s) → Award Contract & Sub-Awards (675 s) → Tranche #1 Lab Grant Release (463 s) → University Labs & PIs.SUPPLIERPrincipalInvestigatorsI1.39 d1Budget & EthicsCompliance CheckC/T 617 sI1.79 d23-Peer ExternalReviewer MatchC/T 733 sI3.79 d3Panel Scoring &Tie-BreakC/T 1,041 sI0.89 d4Award Contract &Sub-AwardsC/T 675 sI0.39 d5Tranche #1 LabGrant ReleaseC/T 463 sI0.39 dCUSTOMERUniversity Labs& PIs28 / files

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Budget & Ethics Compliance Check617 s5 min96%91.5%739 (1.39 d)37
2. 3-Peer External Reviewer Match733 s8 min94%93.8%750 (1.79 d)30
3. Panel Scoring & Tie-Break1,041 s15 min85%88.5%6106 (3.79 d)16
4. Award Contract & Sub-Awards675 s5 min96%97.6%425 (0.89 d)35
5. Tranche #1 Lab Grant Release463 s2 min99%99.4%311 (0.39 d)55

Key figures

Takt time
964 s
Lead time
8.77 d
Value-added time
3,529 s
Process cycle efficiency (PCE)
1.5%
Rolled throughput yield (RTY)
73.7%
Customer demand per day
28 files
Line capacity per day
16 files
Bottleneck
Panel Scoring & Tie-Break

Reading the bottleneck

The bottleneck is "Panel Scoring & Tie-Break": it can process 16 files per day against a demand of 28 files, so it falls short of demand by 41.2%. Once downtime and scrap are counted, its cycle time grows from 1,041 s to 1,384 s, against a takt of 964 s. The largest loss at this step is equipment downtime (uptime 85%), about 184 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Higher Education, Research & Publishing: Higher Education, Research & Publishing