University Hospital Clinical Trial IRB Ethics Review

Product family: Expedited Human-Subject Sign.

Flow: Clinical Investigators → Administrative Protocol Pre-Screen → Biostat & Safety Officer Check → Full IRB Board Monthly Vote → Stipulation Revision Close → Official Study Open Letter → Medical Research Teams

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: University Hospital Clinical Trial IRB Ethics ReviewSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Clinical Investigators → Administrative Protocol Pre-Screen (960 s) → Biostat & Safety Officer Check (1,140 s) → Full IRB Board Monthly Vote (1,620 s) → Stipulation Revision Close (1,050 s) → Official Study Open Letter (720 s) → Medical Research Teams.SUPPLIERClinicalInvestigatorsI1.39 d1AdministrativeProtocol…C/T 960 sI1.78 d2Biostat & SafetyOfficer CheckC/T 1,140 sI3.78 d3Full IRB BoardMonthly VoteC/T 1,620 sI0.89 d4StipulationRevision CloseC/T 1,050 sI0.39 d5Official StudyOpen LetterC/T 720 sI0.39 dCUSTOMERMedicalResearch Teams18 / files

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Administrative Protocol Pre-Screen960 s5 min96%91.5%525 (1.39 d)24
2. Biostat & Safety Officer Check1,140 s8 min94%93.8%532 (1.78 d)20
3. Full IRB Board Monthly Vote1,620 s15 min85%88.5%468 (3.78 d)11
4. Stipulation Revision Close1,050 s5 min96%97.6%316 (0.89 d)22
5. Official Study Open Letter720 s2 min99%99.4%27 (0.39 d)35

Key figures

Takt time
1,500 s
Lead time
8.81 d
Value-added time
5,490 s
Process cycle efficiency (PCE)
2.3%
Rolled throughput yield (RTY)
73.7%
Customer demand per day
18 files
Line capacity per day
11 files
Bottleneck
Full IRB Board Monthly Vote

Reading the bottleneck

The bottleneck is "Full IRB Board Monthly Vote": it can process 11 files per day against a demand of 18 files, so it falls short of demand by 40.8%. Once downtime and scrap are counted, its cycle time grows from 1,620 s to 2,154 s, against a takt of 1,500 s. The largest loss at this step is equipment downtime (uptime 85%), about 286 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Higher Education, Research & Publishing: Higher Education, Research & Publishing