STEM Textbook WCAG-AA Braille & Screen-Reader Prep

Product family: Inclusive Higher-Ed Materials.

Flow: Academic Publishers → Publisher Source XML Ingest → LaTeX MathML Alt-Text Author → Tactile Diagram Emboss Prep → Blind QA Screen-Reader Pass → EPUB3 Accessible Library Drop → Students with Disabilities

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: STEM Textbook WCAG-AA Braille & Screen-Reader PrepSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Academic Publishers → Publisher Source XML Ingest (480 s) → LaTeX MathML Alt-Text Author (570 s) → Tactile Diagram Emboss Prep (810 s) → Blind QA Screen-Reader Pass (525 s) → EPUB3 Accessible Library Drop (360 s) → Students with Disabilities.SUPPLIERAcademicPublishersI1.39 d1Publisher SourceXML IngestC/T 480 sI1.81 d2LaTeX MathMLAlt-Text AuthorC/T 570 sI3.81 d3Tactile DiagramEmboss PrepC/T 810 sI0.89 d4Blind QAScreen-Reader…C/T 525 sI0.39 d5EPUB3 AccessibleLibrary DropC/T 360 sI0.39 dCUSTOMERStudents withDisabilities36 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Publisher Source XML Ingest480 s5 min96%91.5%950 (1.39 d)47
2. LaTeX MathML Alt-Text Author570 s8 min94%93.8%965 (1.81 d)39
3. Tactile Diagram Emboss Prep810 s15 min85%88.5%7137 (3.81 d)21
4. Blind QA Screen-Reader Pass525 s5 min96%97.6%532 (0.89 d)44
5. EPUB3 Accessible Library Drop360 s2 min99%99.4%414 (0.39 d)71

Key figures

Takt time
750 s
Lead time
8.77 d
Value-added time
2,745 s
Process cycle efficiency (PCE)
1.2%
Rolled throughput yield (RTY)
73.7%
Customer demand per day
36 units
Line capacity per day
21 units
Bottleneck
Tactile Diagram Emboss Prep

Reading the bottleneck

The bottleneck is "Tactile Diagram Emboss Prep": it can process 21 units per day against a demand of 36 units, so it falls short of demand by 42.3%. Once downtime and scrap are counted, its cycle time grows from 810 s to 1,077 s, against a takt of 750 s. The largest loss at this step is equipment downtime (uptime 85%), about 143 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Higher Education, Research & Publishing: Higher Education, Research & Publishing