Small-Claims & Commercial Civil Court Filing Desk

Product family: Digital Justice Case Triage.

Flow: Attorneys & Self-Litigants → Electronic Filing & Fee Pay → Clerk Jurisdiction Completeness → Automated E-Mediation Offer → Judicial Law Clerk Brief Prep → Hearing Docket Slot Assigned → Civil Court Judges & Parties

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Small-Claims & Commercial Civil Court Filing DeskSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Attorneys & Self-Litigants → Electronic Filing & Fee Pay (176 s) → Clerk Jurisdiction Completeness (222 s) → Automated E-Mediation Offer (304 s) → Judicial Law Clerk Brief Prep (193 s) → Hearing Docket Slot Assigned (136 s) → Civil Court Judges & Parties.SUPPLIERAttorneys &Self-LitigantsI1.40 d1Electronic Filing& Fee PayC/T 176 sI1.80 d2ClerkJurisdiction…C/T 222 sI3.40 d3AutomatedE-Mediation OfferC/T 304 sI0.91 d4Judicial LawClerk Brief PrepC/T 193 sI0.40 d5Hearing DocketSlot AssignedC/T 136 sI0.40 dCUSTOMERCivil CourtJudges &…95 / cases

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Electronic Filing & Fee Pay176 s5 min97%89.5%19133 (1.40 d)126
2. Clerk Jurisdiction Completeness222 s6 min94%92.5%19171 (1.80 d)99
3. Automated E-Mediation Offer304 s12 min86%89.0%24323 (3.40 d)61
4. Judicial Law Clerk Brief Prep193 s4 min96%97.6%1086 (0.91 d)120
5. Hearing Docket Slot Assigned136 s2 min99%99.2%1038 (0.40 d)187

Key figures

Takt time
284 s
Lead time
8.34 d
Value-added time
1,031 s
Process cycle efficiency (PCE)
0.46%
Rolled throughput yield (RTY)
71.3%
Customer demand per day
95 cases
Line capacity per day
61 cases
Bottleneck
Automated E-Mediation Offer

Reading the bottleneck

The bottleneck is "Automated E-Mediation Offer": it can process 61 cases per day against a demand of 95 cases, so it falls short of demand by 36.0%. Once downtime and scrap are counted, its cycle time grows from 304 s to 397 s, against a takt of 284 s. The largest loss at this step is equipment downtime (uptime 86%), about 49.5 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Public Services, Gov Permits & Registries: Public Services, Gov Permits & Registries