National Patent Office Prior-Art Exam & Grant Flow

Product family: Substantive Examiner Docket.

Flow: PCT & National IP Filers → Formality & Classification IPC → AI Prior-Art Global Search → Primary Examiner 1st Action → Applicant Claim Amendment Loop → Granted Gazette Publication → Inventors & Corporations

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: National Patent Office Prior-Art Exam & Grant FlowSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. PCT & National IP Filers → Formality & Classification IPC (258 s) → AI Prior-Art Global Search (324 s) → Primary Examiner 1st Action (444 s) → Applicant Claim Amendment Loop (282 s) → Granted Gazette Publication (199 s) → Inventors & Corporations.SUPPLIERPCT & NationalIP FilersI1.40 d1Formality &Classification…C/T 258 sI1.80 d2AI Prior-ArtGlobal SearchC/T 324 sI3.40 d3Primary Examiner1st ActionC/T 444 sI0.91 d4Applicant ClaimAmendment LoopC/T 282 sI0.40 d5Granted GazettePublicationC/T 199 sI0.40 dCUSTOMERInventors &Corporations65 / files

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Formality & Classification IPC258 s5 min97%89.5%1391 (1.40 d)86
2. AI Prior-Art Global Search324 s6 min94%92.5%13117 (1.80 d)68
3. Primary Examiner 1st Action444 s12 min86%89.0%16221 (3.40 d)42
4. Applicant Claim Amendment Loop282 s4 min96%97.6%759 (0.91 d)82
5. Granted Gazette Publication199 s2 min99%99.2%726 (0.40 d)128

Key figures

Takt time
415 s
Lead time
8.36 d
Value-added time
1,507 s
Process cycle efficiency (PCE)
0.67%
Rolled throughput yield (RTY)
71.3%
Customer demand per day
65 files
Line capacity per day
42 files
Bottleneck
Primary Examiner 1st Action

Reading the bottleneck

The bottleneck is "Primary Examiner 1st Action": it can process 42 files per day against a demand of 65 files, so it falls short of demand by 36.2%. Once downtime and scrap are counted, its cycle time grows from 444 s to 580 s, against a takt of 415 s. The largest loss at this step is equipment downtime (uptime 86%), about 72.3 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Public Services, Gov Permits & Registries: Public Services, Gov Permits & Registries