Digital Guided All-on-4 Dental Implant Day

Product family: Same-Day 3D-Printed Smile.

Flow: Implant Maker & 3D Lab → CBCT Scan & Digital Smile → Local/IV Anesthesia Prep → Guided Titanium Implant Place → Chairside 3D Crown Milling → Occlusion Bite & Care Exit → Private Prosthodontic Care

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Digital Guided All-on-4 Dental Implant DaySupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Implant Maker & 3D Lab → CBCT Scan & Digital Smile (995 s) → Local/IV Anesthesia Prep (1,306 s) → Guided Titanium Implant Place (1,663 s) → Chairside 3D Crown Milling (1,213 s) → Occlusion Bite & Care Exit (746 s) → Private Prosthodontic Care.SUPPLIERImplant Maker &3D LabI0.59 d1CBCT Scan &Digital SmileC/T 995 sI0.50 d2Local/IVAnesthesia PrepC/T 1,306 sI0.82 d3Guided TitaniumImplant PlaceC/T 1,663 sI0.41 d4Chairside 3DCrown MillingC/T 1,213 sI0.32 d5Occlusion Bite &Care ExitC/T 746 sI0.27 dCUSTOMERPrivateProsthodontic…22 / patients

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. CBCT Scan & Digital Smile995 s5 min97%96.5%413 (0.59 d)31
2. Local/IV Anesthesia Prep1,306 s10 min94%95.8%411 (0.50 d)21
3. Guided Titanium Implant Place1,663 s28 min84%94.0%318 (0.82 d)10
4. Chairside 3D Crown Milling1,213 s6 min95%98.2%29 (0.41 d)23
5. Occlusion Bite & Care Exit746 s4 min98%97.5%27 (0.32 d)40

Key figures

Takt time
1,555 s
Lead time
3.08 d
Value-added time
5,923 s
Process cycle efficiency (PCE)
5.6%
Rolled throughput yield (RTY)
83.2%
Customer demand per day
22 patients
Line capacity per day
10 patients
Bottleneck
Guided Titanium Implant Place

Reading the bottleneck

The bottleneck is "Guided Titanium Implant Place": it can process 10 patients per day against a demand of 22 patients, so it falls short of demand by 52.8%. Once downtime and scrap are counted, its cycle time grows from 1,663 s to 2,106 s, against a takt of 1,555 s. The largest loss at this step is changeovers (28 min every 3 units), about 560 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Surgery, Inpatient & Outpatient Care: Surgery, Inpatient & Outpatient Care