Heavy Lift Wind Blade & Transformer Port Berth

Product family: Out-of-Gauge SPMT Transfer.

Flow: Heavy Lift Charter Ships → Tandem Ship-Crane Tandem Lift → SPMT Self-Propelled Trailer → Lashing Removal & Customs → Heavy Axle Route Escort → Night Curfew Convoy Depart → Inland Wind Farm Corridors

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Heavy Lift Wind Blade & Transformer Port BerthSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Heavy Lift Charter Ships → Tandem Ship-Crane Tandem Lift (2,295 s) → SPMT Self-Propelled Trailer (2,633 s) → Lashing Removal & Customs (3,645 s) → Heavy Axle Route Escort (2,498 s) → Night Curfew Convoy Depart (1,890 s) → Inland Wind Farm Corridors.SUPPLIERHeavy LiftCharter ShipsI1.00 d1Tandem Ship-CraneTandem LiftC/T 2,295 sI2.00 d2SPMTSelf-Propelled…C/T 2,633 sI2.63 d3Lashing Removal &CustomsC/T 3,645 sI0.88 d4Heavy Axle RouteEscortC/T 2,498 sI0.50 d5Night CurfewConvoy DepartC/T 1,890 sI0.75 dCUSTOMERInland WindFarm Corridors8 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Tandem Ship-Crane Tandem Lift2,295 s15 min93%99.1%48 (1.00 d)10
2. SPMT Self-Propelled Trailer2,633 s10 min91%98.4%316 (2.00 d)9
3. Lashing Removal & Customs3,645 s25 min82%92.0%421 (2.63 d)5
4. Heavy Axle Route Escort2,498 s8 min94%97.6%27 (0.88 d)9
5. Night Curfew Convoy Depart1,890 s5 min97%98.6%14 (0.50 d)14

Key figures

Takt time
3,375 s
Lead time
8.23 d
Value-added time
12,961 s
Process cycle efficiency (PCE)
5.8%
Rolled throughput yield (RTY)
86.3%
Customer demand per day
8 units
Line capacity per day
5 units
Bottleneck
Lashing Removal & Customs

Reading the bottleneck

The bottleneck is "Lashing Removal & Customs": it can process 5 units per day against a demand of 8 units, so it falls short of demand by 37.9%. Once downtime and scrap are counted, its cycle time grows from 3,645 s to 4,832 s, against a takt of 3,375 s. The largest loss at this step is equipment downtime (uptime 82%), about 800 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Ports, Maritime, Air Cargo & Customs: Ports, Maritime, Air Cargo & Customs