Automated Bare-Metal Dedicated Server Provision

Product family: 2-Hr Custom Dedicated Host.

Flow: Data Center Hot-Swap Shelf → Inventory Slot Hardware Match → BMC PXE OS Image Stream → NVMe RAID & BGP VLAN Bind → Hardware Burn Check Pass → SSH Key & Root Portal Ready → Cloud Developers & Gaming

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Automated Bare-Metal Dedicated Server ProvisionSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Data Center Hot-Swap Shelf → Inventory Slot Hardware Match (255 s) → BMC PXE OS Image Stream (316 s) → NVMe RAID & BGP VLAN Bind (413 s) → Hardware Burn Check Pass (285 s) → SSH Key & Root Portal Ready (216 s) → Cloud Developers & Gaming.SUPPLIERData CenterHot-Swap ShelfI1.40 d1Inventory SlotHardware MatchC/T 255 sI1.60 d2BMC PXE OS ImageStreamC/T 316 sI2.20 d3NVMe RAID & BGPVLAN BindC/T 413 sI0.90 d4Hardware BurnCheck PassC/T 285 sI0.60 d5SSH Key & RootPortal ReadyC/T 216 sI0.70 dCUSTOMERCloudDevelopers &…140 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Inventory Slot Hardware Match255 s15 min95%98.5%70196 (1.40 d)192
2. BMC PXE OS Image Stream316 s20 min92%97.6%56224 (1.60 d)145
3. NVMe RAID & BGP VLAN Bind413 s25 min85%94.8%70308 (2.20 d)100
4. Hardware Burn Check Pass285 s10 min95%98.2%35126 (0.90 d)169
5. SSH Key & Root Portal Ready216 s8 min97%99.4%2884 (0.60 d)230

Key figures

Takt time
386 s
Lead time
7.43 d
Value-added time
1,485 s
Process cycle efficiency (PCE)
0.37%
Rolled throughput yield (RTY)
89.0%
Customer demand per day
140 units
Line capacity per day
100 units
Bottleneck
NVMe RAID & BGP VLAN Bind

Reading the bottleneck

The bottleneck is "NVMe RAID & BGP VLAN Bind": it can process 100 units per day against a demand of 140 units, so it falls short of demand by 28.9%. Once downtime and scrap are counted, its cycle time grows from 413 s to 513 s, against a takt of 386 s. The largest loss at this step is equipment downtime (uptime 85%), about 72.9 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Cloud Data Centers & Hyperscale Infra: Cloud Data Centers & Hyperscale Infra