Modular Edge Micro-Datacenter Outdoor Container

Product family: 5G Mobile Edge Computing Pod.

Flow: 20ft Insulated ISO Shells → Shell Cutout, Fire Suppr & Floor → In-Row Precision AC & UPS → Rack & Fiber Patch Entry Seal → Full Load-Bank Heat Reject Test → Crane Drop Ready Freight Ship → Telco & Smart City Sites

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Modular Edge Micro-Datacenter Outdoor ContainerSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. 20ft Insulated ISO Shells → Shell Cutout, Fire Suppr & Floor (1,782 s) → In-Row Precision AC & UPS (2,214 s) → Rack & Fiber Patch Entry Seal (2,889 s) → Full Load-Bank Heat Reject Test (1,998 s) → Crane Drop Ready Freight Ship (1,512 s) → Telco & Smart City Sites.SUPPLIER20ft InsulatedISO ShellsI1.40 d1Shell Cutout,Fire Suppr &…C/T 1,782 sI1.60 d2In-Row PrecisionAC & UPSC/T 2,214 sI2.20 d3Rack & FiberPatch Entry SealC/T 2,889 sI0.90 d4Full Load-BankHeat Reject TestC/T 1,998 sI0.60 d5Crane Drop ReadyFreight ShipC/T 1,512 sI0.70 dCUSTOMERTelco & SmartCity Sites10 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Shell Cutout, Fire Suppr & Floor1,782 s15 min95%98.5%514 (1.40 d)13
2. In-Row Precision AC & UPS2,214 s20 min92%97.6%416 (1.60 d)10
3. Rack & Fiber Patch Entry Seal2,889 s25 min85%94.8%522 (2.20 d)7
4. Full Load-Bank Heat Reject Test1,998 s10 min95%98.2%39 (0.90 d)12
5. Crane Drop Ready Freight Ship1,512 s8 min97%99.4%26 (0.60 d)16

Key figures

Takt time
2,700 s
Lead time
7.79 d
Value-added time
10,395 s
Process cycle efficiency (PCE)
4.9%
Rolled throughput yield (RTY)
89.0%
Customer demand per day
10 units
Line capacity per day
7 units
Bottleneck
Rack & Fiber Patch Entry Seal

Reading the bottleneck

The bottleneck is "Rack & Fiber Patch Entry Seal": it can process 7 units per day against a demand of 10 units, so it falls short of demand by 33.1%. Once downtime and scrap are counted, its cycle time grows from 2,889 s to 3,585 s, against a takt of 2,700 s. The largest loss at this step is equipment downtime (uptime 85%), about 510 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Cloud Data Centers & Hyperscale Infra: Cloud Data Centers & Hyperscale Infra