New Cloud Availability Zone Core Fleet Stand-Up

Product family: Multi-Rack Compute/Storage AZ.

Flow: Hyperscale Server Containers → Core Identity & KMS Bootstrap → Spine-Leaf BGP Fabric Burn → Block & Object Storage Pool → Synthetic VM Stress Bench → Public Region Endpoint Open → Public Cloud Customers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: New Cloud Availability Zone Core Fleet Stand-UpSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Hyperscale Server Containers → Core Identity & KMS Bootstrap (8,910 s) → Spine-Leaf BGP Fabric Burn (11,070 s) → Block & Object Storage Pool (14,445 s) → Synthetic VM Stress Bench (9,990 s) → Public Region Endpoint Open (7,560 s) → Public Cloud Customers.SUPPLIERHyperscaleServerContainersI1.50 d1Core Identity &KMS BootstrapC/T 8,910 sI1.50 d2Spine-Leaf BGPFabric BurnC/T 11,070 sI2.25 d3Block & ObjectStorage PoolC/T 14,445 sI1.00 d4Synthetic VMStress BenchC/T 9,990 sI0.50 d5Public RegionEndpoint OpenC/T 7,560 sI0.75 dCUSTOMERPublic CloudCustomers4 / batches

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Core Identity & KMS Bootstrap8,910 s15 min95%98.5%26 (1.50 d)5
2. Spine-Leaf BGP Fabric Burn11,070 s20 min92%97.6%26 (1.50 d)4
3. Block & Object Storage Pool14,445 s25 min85%94.8%29 (2.25 d)3
4. Synthetic VM Stress Bench9,990 s10 min95%98.2%14 (1.00 d)5
5. Public Region Endpoint Open7,560 s8 min97%99.4%12 (0.50 d)7

Key figures

Takt time
13,500 s
Lead time
8.46 d
Value-added time
51,975 s
Process cycle efficiency (PCE)
11.4%
Rolled throughput yield (RTY)
89.0%
Customer demand per day
4 batches
Line capacity per day
3 batches
Bottleneck
Block & Object Storage Pool

Reading the bottleneck

The bottleneck is "Block & Object Storage Pool": it can process 3 batches per day against a demand of 4 batches, so it falls short of demand by 28.9%. Once downtime and scrap are counted, its cycle time grows from 14,445 s to 17,926 s, against a takt of 13,500 s. The largest loss at this step is equipment downtime (uptime 85%), about 2,549 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Cloud Data Centers & Hyperscale Infra: Cloud Data Centers & Hyperscale Infra