1024-GPU InfiniBand NDR Fat-Tree Cluster Cable
Product family: Lossless AI Fabric Deployment.
Flow: 400G/800G OSFP Optical Cables → Switch Topology Port Mapping → Overhead Tray MPO Cable Pull → 800G Transceiver Inspect & Seat → Subnet Manager Topology Lock → All-Reduce RDMA Fabric Audit → Foundation Model Clusters
No account needed. Change any value and the indicators update.
Value stream map
Process steps
| Step | Cycle time | Changeover | Uptime | Yield | Batch | Stock before | Capacity per day |
|---|---|---|---|---|---|---|---|
| 1. Switch Topology Port Mapping | 8,910 s | 15 min | 95% | 98.5% | 2 | 6 (1.50 d) | 5 |
| 2. Overhead Tray MPO Cable Pull | 11,070 s | 20 min | 92% | 97.6% | 2 | 6 (1.50 d) | 4 |
| 3. 800G Transceiver Inspect & Seat | 14,445 s | 25 min | 85% | 94.8% | 2 | 9 (2.25 d) | 3 |
| 4. Subnet Manager Topology Lock | 9,990 s | 10 min | 95% | 98.2% | 1 | 4 (1.00 d) | 5 |
| 5. All-Reduce RDMA Fabric Audit | 7,560 s | 8 min | 97% | 99.4% | 1 | 2 (0.50 d) | 7 |
Key figures
- Takt time
- 13,500 s
- Lead time
- 8.46 d
- Value-added time
- 51,975 s
- Process cycle efficiency (PCE)
- 11.4%
- Rolled throughput yield (RTY)
- 89.0%
- Customer demand per day
- 4 batches
- Line capacity per day
- 3 batches
- Bottleneck
- 800G Transceiver Inspect & Seat
Reading the bottleneck
The bottleneck is "800G Transceiver Inspect & Seat": it can process 3 batches per day against a demand of 4 batches, so it falls short of demand by 28.9%. Once downtime and scrap are counted, its cycle time grows from 14,445 s to 17,926 s, against a takt of 13,500 s. The largest loss at this step is equipment downtime (uptime 85%), about 2,549 s per unit. Reducing that loss is where the first improvement test belongs.
The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.
Other scenarios in this family
More scenarios of Cloud Data Centers & Hyperscale Infra: Cloud Data Centers & Hyperscale Infra
- Factory L11 Pre-Integrated Liquid AI Server Rack
- Data Center Direct-to-Chip CDU Cooling Loop
- Automated Bare-Metal Dedicated Server Provision
- Enterprise Private Colocation Cage Handover
- Modular Edge Micro-Datacenter Outdoor Container
- Automated Immutable Air-Gap Backup Restore Test
- Data Center 2MW Diesel Gen & UPS Load-Bank Test
- Enterprise Internal PKI & TLS Certificate Rotation
- Continuous SOC2 Type-II Automated Evidence Pack
- New Cloud Availability Zone Core Fleet Stand-Up
- Data Center High-Rate VRLA / Lithium String Swap