Municipal Digital BIM Building Permit Review

Product family: Automated Code & Zoning Approval.

Flow: Architectural Firms & Surveyors → Digital Fee & Doc Intake → GIS Zoning & Height Check → IFC Egress & Fire Compliance → Committee Public Hearing Hold → Stamped Building Permit Issue → Real Estate Developers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Municipal Digital BIM Building Permit ReviewSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Architectural Firms & Surveyors → Digital Fee & Doc Intake (761 s) → GIS Zoning & Height Check (1,313 s) → IFC Egress & Fire Compliance (1,031 s) → Committee Public Hearing Hold (859 s) → Stamped Building Permit Issue (589 s) → Real Estate Developers.SUPPLIERArchitecturalFirms &SurveyorsI1.50 d1Digital Fee & DocIntakeC/T 761 sI3.18 d2GIS Zoning &Height CheckC/T 1,313 sI1.82 d3IFC Egress & FireComplianceC/T 1,031 sI0.91 d4Committee PublicHearing HoldC/T 859 sI0.41 d5Stamped BuildingPermit IssueC/T 589 sI0.41 dCUSTOMERReal EstateDevelopers22 / files

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Digital Fee & Doc Intake761 s10 min97%91.5%733 (1.50 d)29
2. GIS Zoning & Height Check1,313 s15 min86%88.5%670 (3.18 d)14
3. IFC Egress & Fire Compliance1,031 s15 min91%95.8%440 (1.82 d)19
4. Committee Public Hearing Hold859 s8 min95%97.8%320 (0.91 d)25
5. Stamped Building Permit Issue589 s5 min98%99.1%29 (0.41 d)39

Key figures

Takt time
1,227 s
Lead time
8.40 d
Value-added time
4,553 s
Process cycle efficiency (PCE)
2.0%
Rolled throughput yield (RTY)
75.2%
Customer demand per day
22 files
Line capacity per day
14 files
Bottleneck
GIS Zoning & Height Check

Reading the bottleneck

The bottleneck is "GIS Zoning & Height Check": it can process 14 files per day against a demand of 22 files, so it falls short of demand by 37.6%. Once downtime and scrap are counted, its cycle time grows from 1,313 s to 1,725 s, against a takt of 1,227 s. The largest loss at this step is equipment downtime (uptime 86%), about 214 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Real Estate Dev, Permits & Facility Ops: Real Estate Dev, Permits & Facility Ops