Municipal Digital BIM Building Permit Review
Product family: Automated Code & Zoning Approval.
Flow: Architectural Firms & Surveyors → Digital Fee & Doc Intake → GIS Zoning & Height Check → IFC Egress & Fire Compliance → Committee Public Hearing Hold → Stamped Building Permit Issue → Real Estate Developers
No account needed. Change any value and the indicators update.
Value stream map
Process steps
| Step | Cycle time | Changeover | Uptime | Yield | Batch | Stock before | Capacity per day |
|---|---|---|---|---|---|---|---|
| 1. Digital Fee & Doc Intake | 761 s | 10 min | 97% | 91.5% | 7 | 33 (1.50 d) | 29 |
| 2. GIS Zoning & Height Check | 1,313 s | 15 min | 86% | 88.5% | 6 | 70 (3.18 d) | 14 |
| 3. IFC Egress & Fire Compliance | 1,031 s | 15 min | 91% | 95.8% | 4 | 40 (1.82 d) | 19 |
| 4. Committee Public Hearing Hold | 859 s | 8 min | 95% | 97.8% | 3 | 20 (0.91 d) | 25 |
| 5. Stamped Building Permit Issue | 589 s | 5 min | 98% | 99.1% | 2 | 9 (0.41 d) | 39 |
Key figures
- Takt time
- 1,227 s
- Lead time
- 8.40 d
- Value-added time
- 4,553 s
- Process cycle efficiency (PCE)
- 2.0%
- Rolled throughput yield (RTY)
- 75.2%
- Customer demand per day
- 22 files
- Line capacity per day
- 14 files
- Bottleneck
- GIS Zoning & Height Check
Reading the bottleneck
The bottleneck is "GIS Zoning & Height Check": it can process 14 files per day against a demand of 22 files, so it falls short of demand by 37.6%. Once downtime and scrap are counted, its cycle time grows from 1,313 s to 1,725 s, against a takt of 1,227 s. The largest loss at this step is equipment downtime (uptime 86%), about 214 s per unit. Reducing that loss is where the first improvement test belongs.
The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.
Other scenarios in this family
More scenarios of Real Estate Dev, Permits & Facility Ops: Real Estate Dev, Permits & Facility Ops
- Corporate Office Fit-Out Design-Build Handover
- Multi-Site Commercial HVAC Preventive Maintenance
- Pre-Handover New Apartment Snagging & Close
- Commercial Building Deep Energy & Heat-Pump Retro
- Annual Statutory Elevator & Escalator Safety Audit
- Pre-Demolition Hazardous Asbestos Abatement Flow
- Build-to-Rent Apartment Move-Out Make-Ready
- Institutional Portfolio RICS Property Appraisal
- Multi-Tenant Commercial Smart Water/Elec Metering
- Multi-Unit Residential Garage EV Charger Install
- Drone LiDAR Topographic & Cadastral Land Survey