24-Hour Rapid Chest Pain Observation Unit

Product family: High-Sensitivity Troponin Track.

Flow: Cardiology Treadmill & Troponin → Triage ECG & Rule-In Check → 0-Hr & 3-Hr hs-Troponin → Stress Echo / CT Angio → Cardiologist Telemetry Clear → Stat Outpatient Follow-Up → Cardiology Clinic / Home

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: 24-Hour Rapid Chest Pain Observation UnitSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Cardiology Treadmill & Troponin → Triage ECG & Rule-In Check (1,194 s) → 0-Hr & 3-Hr hs-Troponin (1,663 s) → Stress Echo / CT Angio (2,281 s) → Cardiologist Telemetry Clear (1,791 s) → Stat Outpatient Follow-Up (1,322 s) → Cardiology Clinic / Home.SUPPLIERCardiologyTreadmill &TroponinI0.34 d1Triage ECG &Rule-In CheckC/T 1,194 sI0.55 d20-Hr & 3-Hrhs-TroponinC/T 1,663 sI1.16 d3Stress Echo / CTAngioC/T 2,281 sI0.76 d4CardiologistTelemetry ClearC/T 1,791 sI0.66 d5Stat OutpatientFollow-UpC/T 1,322 sI0.26 dCUSTOMERCardiologyClinic / Home38 / patients

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Triage ECG & Rule-In Check1,194 s2 min98%97.5%413 (0.34 d)64
2. 0-Hr & 3-Hr hs-Troponin1,663 s4 min94%95.8%421 (0.55 d)43
3. Stress Echo / CT Angio2,281 s12 min85%92.0%844 (1.16 d)27
4. Cardiologist Telemetry Clear1,791 s6 min92%96.5%429 (0.76 d)38
5. Stat Outpatient Follow-Up1,322 s5 min94%97.2%425 (0.66 d)54

Key figures

Takt time
2,132 s
Lead time
3.84 d
Value-added time
8,251 s
Process cycle efficiency (PCE)
2.7%
Rolled throughput yield (RTY)
80.6%
Customer demand per day
38 patients
Line capacity per day
27 patients
Bottleneck
Stress Echo / CT Angio

Reading the bottleneck

The bottleneck is "Stress Echo / CT Angio": it can process 27 patients per day against a demand of 38 patients, so it falls short of demand by 30.0%. Once downtime and scrap are counted, its cycle time grows from 2,281 s to 2,917 s, against a takt of 2,132 s. The largest loss at this step is equipment downtime (uptime 85%), about 403 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Emergency Medicine & Urgent Pathways: Emergency Medicine & Urgent Pathways