Toxicology & Acute Overdose Decontamination Track

Product family: Rapid Antidote & Tox Lab.

Flow: Regional Poison Control → Poison Center Phone Consult → Vitals, ECG QT & Tox Urine → Charcoal / Antidote Infuse → Telemetry Clearance Window → Behavioral Safety Check Exit → ED Tox / Telemetry Ward

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Toxicology & Acute Overdose Decontamination TrackSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Regional Poison Control → Poison Center Phone Consult (2,062 s) → Vitals, ECG QT & Tox Urine (2,872 s) → Charcoal / Antidote Infuse (3,940 s) → Telemetry Clearance Window (3,093 s) → Behavioral Safety Check Exit (2,283 s) → ED Tox / Telemetry Ward.SUPPLIERRegional PoisonControlI0.36 d1Poison CenterPhone ConsultC/T 2,062 sI0.55 d2Vitals, ECG QT &Tox UrineC/T 2,872 sI1.14 d3Charcoal /Antidote InfuseC/T 3,940 sI0.77 d4TelemetryClearance WindowC/T 3,093 sI0.64 d5Behavioral SafetyCheck ExitC/T 2,283 sI0.27 dCUSTOMERED Tox /Telemetry Ward22 / patients

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Poison Center Phone Consult2,062 s2 min98%97.5%28 (0.36 d)37
2. Vitals, ECG QT & Tox Urine2,872 s4 min94%95.8%212 (0.55 d)25
3. Charcoal / Antidote Infuse3,940 s12 min85%92.0%425 (1.14 d)15
4. Telemetry Clearance Window3,093 s6 min92%96.5%217 (0.77 d)22
5. Behavioral Safety Check Exit2,283 s5 min94%97.2%214 (0.64 d)31

Key figures

Takt time
3,682 s
Lead time
3.90 d
Value-added time
14,250 s
Process cycle efficiency (PCE)
4.5%
Rolled throughput yield (RTY)
80.6%
Customer demand per day
22 patients
Line capacity per day
15 patients
Bottleneck
Charcoal / Antidote Infuse

Reading the bottleneck

The bottleneck is "Charcoal / Antidote Infuse": it can process 15 patients per day against a demand of 22 patients, so it falls short of demand by 30.5%. Once downtime and scrap are counted, its cycle time grows from 3,940 s to 5,038 s, against a takt of 3,682 s. The largest loss at this step is equipment downtime (uptime 85%), about 695 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Emergency Medicine & Urgent Pathways: Emergency Medicine & Urgent Pathways