Acute Ophthalmic Trauma & Retinal Detachment ER

Product family: Slit-Lamp Urgent Eye Track.

Flow: Sterile Fluorescein & Drops → Snellen Vision & Chemical Wash → Ophthalmic Nurse Drop Prep → Slit-Lamp & OCT Macula Scan → IOP Check or Laser Sealing → Shield Patch & 24h Return → Vitreoretinal OR / Home

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Acute Ophthalmic Trauma & Retinal Detachment ERSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Sterile Fluorescein & Drops → Snellen Vision & Chemical Wash (315 s) → Ophthalmic Nurse Drop Prep (439 s) → Slit-Lamp & OCT Macula Scan (602 s) → IOP Check or Laser Sealing (473 s) → Shield Patch & 24h Return (349 s) → Vitreoretinal OR / Home.SUPPLIERSterileFluorescein &DropsI0.35 d1Snellen Vision &Chemical WashC/T 315 sI0.54 d2Ophthalmic NurseDrop PrepC/T 439 sI1.15 d3Slit-Lamp & OCTMacula ScanC/T 602 sI0.75 d4IOP Check orLaser SealingC/T 473 sI0.65 d5Shield Patch &24h ReturnC/T 349 sI0.25 dCUSTOMERVitreoretinalOR / Home48 / patients

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Snellen Vision & Chemical Wash315 s2 min98%97.5%517 (0.35 d)78
2. Ophthalmic Nurse Drop Prep439 s4 min94%95.8%526 (0.54 d)51
3. Slit-Lamp & OCT Macula Scan602 s12 min85%92.0%1055 (1.15 d)31
4. IOP Check or Laser Sealing473 s6 min92%96.5%536 (0.75 d)44
5. Shield Patch & 24h Return349 s5 min94%97.2%531 (0.65 d)63

Key figures

Takt time
563 s
Lead time
3.77 d
Value-added time
2,178 s
Process cycle efficiency (PCE)
2.1%
Rolled throughput yield (RTY)
80.6%
Customer demand per day
48 patients
Line capacity per day
31 patients
Bottleneck
Slit-Lamp & OCT Macula Scan

Reading the bottleneck

The bottleneck is "Slit-Lamp & OCT Macula Scan": it can process 31 patients per day against a demand of 48 patients, so it falls short of demand by 36.3%. Once downtime and scrap are counted, its cycle time grows from 602 s to 770 s, against a takt of 563 s. The largest loss at this step is equipment downtime (uptime 85%), about 106 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Emergency Medicine & Urgent Pathways: Emergency Medicine & Urgent Pathways