Code STEMI Heart-Attack Door-to-Balloon <60m

Product family: Emergency Cardiac PCI Track.

Flow: EMS Telemetry ECG Feed → EMS Pre-Hospital 12-Lead → ED Bypass Direct-to-Cath → Radial Puncture & Angioplasty → Thrombus & Balloon Open <45m → Coronary ICU Transfer → CCU Intensive Cardiac Care

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Code STEMI Heart-Attack Door-to-Balloon <60mSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. EMS Telemetry ECG Feed → EMS Pre-Hospital 12-Lead (7,560 s) → ED Bypass Direct-to-Cath (10,530 s) → Radial Puncture & Angioplasty (14,445 s) → Thrombus & Balloon Open <45m (11,340 s) → Coronary ICU Transfer (8,370 s) → CCU Intensive Cardiac Care.SUPPLIEREMS TelemetryECG FeedI0.33 d1EMS Pre-Hospital12-LeadC/T 7,560 sI0.50 d2ED BypassDirect-to-CathC/T 10,530 sI1.17 d3Radial Puncture &AngioplastyC/T 14,445 sI0.83 d4Thrombus &Balloon Open <45mC/T 11,340 sI0.67 d5Coronary ICUTransferC/T 8,370 sI0.33 dCUSTOMERCCU IntensiveCardiac Care6 / patients

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. EMS Pre-Hospital 12-Lead7,560 s2 min98%97.5%12 (0.33 d)10
2. ED Bypass Direct-to-Cath10,530 s4 min94%95.8%13 (0.50 d)7
3. Radial Puncture & Angioplasty14,445 s12 min85%92.0%17 (1.17 d)4
4. Thrombus & Balloon Open <45m11,340 s6 min92%96.5%15 (0.83 d)6
5. Coronary ICU Transfer8,370 s5 min94%97.2%14 (0.67 d)9

Key figures

Takt time
13,500 s
Lead time
4.48 d
Value-added time
52,245 s
Process cycle efficiency (PCE)
14.4%
Rolled throughput yield (RTY)
80.6%
Customer demand per day
6 patients
Line capacity per day
4 patients
Bottleneck
Radial Puncture & Angioplasty

Reading the bottleneck

The bottleneck is "Radial Puncture & Angioplasty": it can process 4 patients per day against a demand of 6 patients, so it falls short of demand by 27.6%. Once downtime and scrap are counted, its cycle time grows from 14,445 s to 18,472 s, against a takt of 13,500 s. The largest loss at this step is equipment downtime (uptime 85%), about 2,549 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Emergency Medicine & Urgent Pathways: Emergency Medicine & Urgent Pathways