Virtual & Acute Orthopedic Cast Fracture ER

Product family: Same-Day Splint & X-Ray Flow.

Flow: Fiberglass Cast & Digital X-Ray → Point-of-Injury Pain & Ice → Direct Digital Limb X-Ray → PACS Tele-Ortho Fracture Review → Cast Room Fiberglass Mold → Crutch Fit & Physio Booklet → Ortho Outpatient Rehab

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Virtual & Acute Orthopedic Cast Fracture ERSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Fiberglass Cast & Digital X-Ray → Point-of-Injury Pain & Ice (403 s) → Direct Digital Limb X-Ray (562 s) → PACS Tele-Ortho Fracture Review (770 s) → Cast Room Fiberglass Mold (605 s) → Crutch Fit & Physio Booklet (446 s) → Ortho Outpatient Rehab.SUPPLIERFiberglass Cast& Digital X-RayI0.35 d1Point-of-InjuryPain & IceC/T 403 sI0.55 d2Direct DigitalLimb X-RayC/T 562 sI1.15 d3PACS Tele-OrthoFracture ReviewC/T 770 sI0.75 d4Cast RoomFiberglass MoldC/T 605 sI0.65 d5Crutch Fit &Physio BookletC/T 446 sI0.25 dCUSTOMEROrthoOutpatient…75 / patients

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Point-of-Injury Pain & Ice403 s2 min98%97.5%826 (0.35 d)125
2. Direct Digital Limb X-Ray562 s4 min94%95.8%841 (0.55 d)83
3. PACS Tele-Ortho Fracture Review770 s12 min85%92.0%1586 (1.15 d)51
4. Cast Room Fiberglass Mold605 s6 min92%96.5%856 (0.75 d)74
5. Crutch Fit & Physio Booklet446 s5 min94%97.2%849 (0.65 d)105

Key figures

Takt time
720 s
Lead time
3.74 d
Value-added time
2,786 s
Process cycle efficiency (PCE)
1.4%
Rolled throughput yield (RTY)
80.6%
Customer demand per day
75 patients
Line capacity per day
51 patients
Bottleneck
PACS Tele-Ortho Fracture Review

Reading the bottleneck

The bottleneck is "PACS Tele-Ortho Fracture Review": it can process 51 patients per day against a demand of 75 patients, so it falls short of demand by 31.8%. Once downtime and scrap are counted, its cycle time grows from 770 s to 985 s, against a takt of 720 s. The largest loss at this step is equipment downtime (uptime 85%), about 136 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Emergency Medicine & Urgent Pathways: Emergency Medicine & Urgent Pathways