Airport Flagship Business Lounge Peak Wave

Product family: Buffet, Shower & Seat Refresh.

Flow: Terminal Commissary Kitchen → QR Boarding Pass Welcome → 15-Min Shower Suite Turnaround → Hot Buffet & Espresso Refill → Seat Bussing & Tray Clear → Boarding Gate Call Prompt → Departing Frequent Flyers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Airport Flagship Business Lounge Peak WaveSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Terminal Commissary Kitchen → QR Boarding Pass Welcome (41.0 s) → 15-Min Shower Suite Turnaround (48.0 s) → Hot Buffet & Espresso Refill (68.0 s) → Seat Bussing & Tray Clear (43.0 s) → Boarding Gate Call Prompt (33.0 s) → Departing Frequent Flyers.SUPPLIERTerminalCommissaryKitchenI0.50 d1QR Boarding PassWelcomeC/T 41.0 sI0.70 d215-Min ShowerSuite TurnaroundC/T 48.0 sI1.20 d3Hot Buffet &Espresso RefillC/T 68.0 sI0.45 d4Seat Bussing &Tray ClearC/T 43.0 sI0.25 d5Boarding GateCall PromptC/T 33.0 sI0.40 dCUSTOMERDepartingFrequent Flyers850 / orders

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. QR Boarding Pass Welcome41.0 s3 min97%98.5%170425 (0.50 d)1,237
2. 15-Min Shower Suite Turnaround48.0 s5 min95%98.1%170595 (0.70 d)1,019
3. Hot Buffet & Espresso Refill68.0 s8 min88%91.0%1281,020 (1.20 d)598
4. Seat Bussing & Tray Clear43.0 s2 min96%96.5%85383 (0.45 d)1,138
5. Boarding Gate Call Prompt33.0 s2 min99%99.2%85213 (0.25 d)1,571

Key figures

Takt time
63.5 s
Lead time
3.51 d
Value-added time
233 s
Process cycle efficiency (PCE)
0.12%
Rolled throughput yield (RTY)
84.2%
Customer demand per day
850 orders
Line capacity per day
598 orders
Bottleneck
Hot Buffet & Espresso Refill

Reading the bottleneck

The bottleneck is "Hot Buffet & Espresso Refill": it can process 598 orders per day against a demand of 850 orders, so it falls short of demand by 29.6%. Once downtime and scrap are counted, its cycle time grows from 68.0 s to 84.9 s, against a takt of 63.5 s. The largest loss at this step is equipment downtime (uptime 88%), about 9.3 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Hospitality, Hotels, Dining & Travel Ops: Hospitality, Hotels, Dining & Travel Ops