Executive Private Aviation FBO Quick Turn

Product family: 30-Min Jet Fuel & Ramp Turn.

Flow: Jet-A1 Truck & VIP Catering → Flight Plan Slot & Ramp Spot → VIP Customs & Bag Valet Van → Jet-A1 Fuel, Lav & GPU Service → Cabin Vacuum & Ice/Catering → Clearance Tug Push Back → Private Jet Passengers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Executive Private Aviation FBO Quick TurnSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Jet-A1 Truck & VIP Catering → Flight Plan Slot & Ramp Spot (1,234 s) → VIP Customs & Bag Valet Van (1,466 s) → Jet-A1 Fuel, Lav & GPU Service (2,064 s) → Cabin Vacuum & Ice/Catering (1,311 s) → Clearance Tug Push Back (1,003 s) → Private Jet Passengers.SUPPLIERJet-A1 Truck &VIP CateringI0.50 d1Flight Plan Slot& Ramp SpotC/T 1,234 sI0.71 d2VIP Customs & BagValet VanC/T 1,466 sI1.21 d3Jet-A1 Fuel, Lav& GPU ServiceC/T 2,064 sI0.46 d4Cabin Vacuum &Ice/CateringC/T 1,311 sI0.25 d5Clearance TugPush BackC/T 1,003 sI0.39 dCUSTOMERPrivate JetPassengers28 / cases

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Flight Plan Slot & Ramp Spot1,234 s3 min97%98.5%614 (0.50 d)41
2. VIP Customs & Bag Valet Van1,466 s5 min95%98.1%620 (0.71 d)33
3. Jet-A1 Fuel, Lav & GPU Service2,064 s8 min88%91.0%434 (1.21 d)20
4. Cabin Vacuum & Ice/Catering1,311 s2 min96%96.5%313 (0.46 d)37
5. Clearance Tug Push Back1,003 s2 min99%99.2%37 (0.25 d)52

Key figures

Takt time
1,929 s
Lead time
3.67 d
Value-added time
7,078 s
Process cycle efficiency (PCE)
3.6%
Rolled throughput yield (RTY)
84.2%
Customer demand per day
28 cases
Line capacity per day
20 cases
Bottleneck
Jet-A1 Fuel, Lav & GPU Service

Reading the bottleneck

The bottleneck is "Jet-A1 Fuel, Lav & GPU Service": it can process 20 cases per day against a demand of 28 cases, so it falls short of demand by 29.8%. Once downtime and scrap are counted, its cycle time grows from 2,064 s to 2,577 s, against a takt of 1,929 s. The largest loss at this step is equipment downtime (uptime 88%), about 281 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Hospitality, Hotels, Dining & Travel Ops: Hospitality, Hotels, Dining & Travel Ops