High-Volume Hotel Sheet Tunnel Washer Line

Product family: 50-Ton/Day Barrier Laundry.

Flow: City 4/5-Star Hotels → UHF RFID Bag Dump & Sort → 14-Compartment Tunnel Washer → 60-Bar Centrifugal Press Cake → High-Speed Ironer & Auto Fold → RFID Cage Dispatch by Property → Hotel Linen Lockers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: High-Volume Hotel Sheet Tunnel Washer LineSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. City 4/5-Star Hotels → UHF RFID Bag Dump & Sort (7.7 s) → 14-Compartment Tunnel Washer (9.1 s) → 60-Bar Centrifugal Press Cake (12.8 s) → High-Speed Ironer & Auto Fold (8.2 s) → RFID Cage Dispatch by Property (6.2 s) → Hotel Linen Lockers.SUPPLIERCity 4/5-StarHotelsI0.50 d1UHF RFID Bag Dump& SortC/T 7.7 sI0.70 d214-CompartmentTunnel WasherC/T 9.1 sI1.20 d360-BarCentrifugal Pres…C/T 12.8 sI0.45 d4High-Speed Ironer& Auto FoldC/T 8.2 sI0.25 d5RFID CageDispatch by…C/T 6.2 sI0.40 dCUSTOMERHotel LinenLockers4,500 / crates

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. UHF RFID Bag Dump & Sort7.7 s3 min97%98.5%9002,250 (0.50 d)6,589
2. 14-Compartment Tunnel Washer9.1 s5 min95%98.1%9003,150 (0.70 d)5,377
3. 60-Bar Centrifugal Press Cake12.8 s8 min88%91.0%6755,400 (1.20 d)3,178
4. High-Speed Ironer & Auto Fold8.2 s2 min96%96.5%4502,025 (0.45 d)5,965
5. RFID Cage Dispatch by Property6.2 s2 min99%99.2%4501,125 (0.25 d)8,364

Key figures

Takt time
12.0 s
Lead time
3.50 d
Value-added time
44.0 s
Process cycle efficiency (PCE)
0.023%
Rolled throughput yield (RTY)
84.2%
Customer demand per day
4,500 crates
Line capacity per day
3,178 crates
Bottleneck
60-Bar Centrifugal Press Cake

Reading the bottleneck

The bottleneck is "60-Bar Centrifugal Press Cake": it can process 3,178 crates per day against a demand of 4,500 crates, so it falls short of demand by 29.4%. Once downtime and scrap are counted, its cycle time grows from 12.8 s to 16.0 s, against a takt of 12.0 s. The largest loss at this step is equipment downtime (uptime 88%), about 1.7 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Hospitality, Hotels, Dining & Travel Ops: Hospitality, Hotels, Dining & Travel Ops