Autologous Patient-Specific CAR-T Therapy Lot

Product family: Personalized Vein-to-Vein Cells.

Flow: Leukapheresis Hospital Hubs → Cryo Thaw & CD4/CD8 Select → Lentiviral Activation Transduct → 10-Day Gas-Permeable Vessel Expansion → Cryo-Bags DMSO Fill & Freeze → QP Sterility & Mycoplasma → CAR-T Treatment Centers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Autologous Patient-Specific CAR-T Therapy LotSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Leukapheresis Hospital Hubs → Cryo Thaw & CD4/CD8 Select (2,777 s) → Lentiviral Activation Transduct (3,317 s) → 10-Day Gas-Permeable Vessel Expansion (4,166 s) → Cryo-Bags DMSO Fill & Freeze (3,009 s) → QP Sterility & Mycoplasma (2,546 s) → CAR-T Treatment Centers.SUPPLIERLeukapheresisHospital HubsI1.57 d1Cryo Thaw &CD4/CD8 SelectC/T 2,777 sI1.79 d2LentiviralActivation…C/T 3,317 sI2.43 d310-DayGas-Permeable…C/T 4,166 sI1.21 d4Cryo-Bags DMSOFill & FreezeC/T 3,009 sI1.50 d5QP Sterility &MycoplasmaC/T 2,546 sI1.50 dCUSTOMERCAR-T TreatmentCenters14 / patients

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Cryo Thaw & CD4/CD8 Select2,777 s30 min95%98.4%1422 (1.57 d)18
2. Lentiviral Activation Transduct3,317 s40 min91%97.2%2125 (1.79 d)14
3. 10-Day Gas-Permeable Vessel Expansion4,166 s60 min84%94.5%1434 (2.43 d)10
4. Cryo-Bags DMSO Fill & Freeze3,009 s25 min93%98.1%717 (1.21 d)15
5. QP Sterility & Mycoplasma2,546 s15 min95%97.8%1121 (1.50 d)19

Key figures

Takt time
3,857 s
Lead time
10.3 d
Value-added time
15,815 s
Process cycle efficiency (PCE)
2.8%
Rolled throughput yield (RTY)
86.7%
Customer demand per day
14 patients
Line capacity per day
10 patients
Bottleneck
10-Day Gas-Permeable Vessel Expansion

Reading the bottleneck

The bottleneck is "10-Day Gas-Permeable Vessel Expansion": it can process 10 patients per day against a demand of 14 patients, so it falls short of demand by 31.4%. Once downtime and scrap are counted, its cycle time grows from 4,166 s to 5,248 s, against a takt of 3,857 s. The largest loss at this step is equipment downtime (uptime 84%), about 794 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Biologics, mRNA & Cell Therapy: Biologics, mRNA & Cell Therapy