Animal-Origin-Free Dry Powder Cell Media Mill

Product family: Chemically Defined CHO Media.

Flow: USP Amino Acids & Vitamins → 45-Ingredient Trace Weighing → Cryo Pin-Mill Co-Grinding → V-Blender CV<2% Uniformity → Foil Drum Nitrogen Inerting → Cell Growth Assay vs Ref Lot → Biologics Manufacturing Plants

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Animal-Origin-Free Dry Powder Cell Media MillSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. USP Amino Acids & Vitamins → 45-Ingredient Trace Weighing (432 s) → Cryo Pin-Mill Co-Grinding (516 s) → V-Blender CV<2% Uniformity (648 s) → Foil Drum Nitrogen Inerting (468 s) → Cell Growth Assay vs Ref Lot (396 s) → Biologics Manufacturing Plants.SUPPLIERUSP Amino Acids& VitaminsI1.60 d145-IngredientTrace WeighingC/T 432 sI1.80 d2Cryo Pin-MillCo-GrindingC/T 516 sI2.40 d3V-Blender CV<2%UniformityC/T 648 sI1.20 d4Foil DrumNitrogen InertingC/T 468 sI1.50 d5Cell Growth Assayvs Ref LotC/T 396 sI1.50 dCUSTOMERBiologicsManufacturing…90 / batches

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. 45-Ingredient Trace Weighing432 s30 min95%98.4%90144 (1.60 d)113
2. Cryo Pin-Mill Co-Grinding516 s40 min91%97.2%135162 (1.80 d)90
3. V-Blender CV<2% Uniformity648 s60 min84%94.5%90216 (2.40 d)62
4. Foil Drum Nitrogen Inerting468 s25 min93%98.1%45108 (1.20 d)99
5. Cell Growth Assay vs Ref Lot396 s15 min95%97.8%72135 (1.50 d)124

Key figures

Takt time
600 s
Lead time
10.0 d
Value-added time
2,460 s
Process cycle efficiency (PCE)
0.45%
Rolled throughput yield (RTY)
86.7%
Customer demand per day
90 batches
Line capacity per day
62 batches
Bottleneck
V-Blender CV<2% Uniformity

Reading the bottleneck

The bottleneck is "V-Blender CV<2% Uniformity": it can process 62 batches per day against a demand of 90 batches, so it falls short of demand by 31.4%. Once downtime and scrap are counted, its cycle time grows from 648 s to 816 s, against a takt of 600 s. The largest loss at this step is equipment downtime (uptime 84%), about 123 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Biologics, mRNA & Cell Therapy: Biologics, mRNA & Cell Therapy