GMP Linearized Plasmid DNA Template Plant

Product family: mRNA In-Vitro Synthesis Prep.

Flow: Chromatography Salt Suppliers → High-Density Ferment Harvest → Gentle Alkaline Lysis Loop → HIC & AEC Endotoxin Removal → Restriction Enzyme Linearize → qPCR Supercoiled >95% Audit → mRNA Vaccine Factories

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: GMP Linearized Plasmid DNA Template PlantSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Chromatography Salt Suppliers → High-Density Ferment Harvest (1,555 s) → Gentle Alkaline Lysis Loop (1,858 s) → HIC & AEC Endotoxin Removal (2,333 s) → Restriction Enzyme Linearize (1,685 s) → qPCR Supercoiled >95% Audit (1,426 s) → mRNA Vaccine Factories.SUPPLIERChromatographySalt SuppliersI1.60 d1High-DensityFerment HarvestC/T 1,555 sI1.80 d2Gentle AlkalineLysis LoopC/T 1,858 sI2.40 d3HIC & AECEndotoxin RemovalC/T 2,333 sI1.20 d4RestrictionEnzyme LinearizeC/T 1,685 sI1.52 d5qPCR Supercoiled>95% AuditC/T 1,426 sI1.52 dCUSTOMERmRNA VaccineFactories25 / batches

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. High-Density Ferment Harvest1,555 s30 min95%98.4%2540 (1.60 d)31
2. Gentle Alkaline Lysis Loop1,858 s40 min91%97.2%3845 (1.80 d)25
3. HIC & AEC Endotoxin Removal2,333 s60 min84%94.5%2560 (2.40 d)17
4. Restriction Enzyme Linearize1,685 s25 min93%98.1%1330 (1.20 d)28
5. qPCR Supercoiled >95% Audit1,426 s15 min95%97.8%2038 (1.52 d)34

Key figures

Takt time
2,160 s
Lead time
10.2 d
Value-added time
8,857 s
Process cycle efficiency (PCE)
1.6%
Rolled throughput yield (RTY)
86.7%
Customer demand per day
25 batches
Line capacity per day
17 batches
Bottleneck
HIC & AEC Endotoxin Removal

Reading the bottleneck

The bottleneck is "HIC & AEC Endotoxin Removal": it can process 17 batches per day against a demand of 25 batches, so it falls short of demand by 31.4%. Once downtime and scrap are counted, its cycle time grows from 2,333 s to 2,939 s, against a takt of 2,160 s. The largest loss at this step is equipment downtime (uptime 84%), about 444 s per unit. Reducing that loss is where the first improvement test belongs.