Recombinant Antigen + Liposome Vaccine Bulk

Product family: Next-Gen Adjuvanted Vaccines.

Flow: Squalene & QS-21 Suppliers → Sf9 Insect Cell Bioreactor → TFF Diafiltration & Capture → Liposome High-Shear Size 90nm → Sterile 0.22um Bulk Hold → DLS Particle Size & Endotoxin → Global Pandemic Vaccine Fill

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Recombinant Antigen + Liposome Vaccine BulkSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Squalene & QS-21 Suppliers → Sf9 Insect Cell Bioreactor (972 s) → TFF Diafiltration & Capture (1,161 s) → Liposome High-Shear Size 90nm (1,458 s) → Sterile 0.22um Bulk Hold (1,053 s) → DLS Particle Size & Endotoxin (891 s) → Global Pandemic Vaccine Fill.SUPPLIERSqualene &QS-21 SuppliersI1.60 d1Sf9 Insect CellBioreactorC/T 972 sI1.80 d2TFF Diafiltration& CaptureC/T 1,161 sI2.40 d3LiposomeHigh-Shear Size…C/T 1,458 sI1.20 d4Sterile 0.22umBulk HoldC/T 1,053 sI1.50 d5DLS Particle Size& EndotoxinC/T 891 sI1.50 dCUSTOMERGlobal PandemicVaccine Fill40 / batches

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Sf9 Insect Cell Bioreactor972 s30 min95%98.4%4064 (1.60 d)50
2. TFF Diafiltration & Capture1,161 s40 min91%97.2%6072 (1.80 d)40
3. Liposome High-Shear Size 90nm1,458 s60 min84%94.5%4096 (2.40 d)27
4. Sterile 0.22um Bulk Hold1,053 s25 min93%98.1%2048 (1.20 d)44
5. DLS Particle Size & Endotoxin891 s15 min95%97.8%3260 (1.50 d)55

Key figures

Takt time
1,350 s
Lead time
10.1 d
Value-added time
5,535 s
Process cycle efficiency (PCE)
1.0%
Rolled throughput yield (RTY)
86.7%
Customer demand per day
40 batches
Line capacity per day
27 batches
Bottleneck
Liposome High-Shear Size 90nm

Reading the bottleneck

The bottleneck is "Liposome High-Shear Size 90nm": it can process 27 batches per day against a demand of 40 batches, so it falls short of demand by 31.4%. Once downtime and scrap are counted, its cycle time grows from 1,458 s to 1,837 s, against a takt of 1,350 s. The largest loss at this step is equipment downtime (uptime 84%), about 278 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.