Municipal Ambulance Fleet Bio-Wash & Narcotic Stock

Product family: 20-Min Hub Make-Ready Shift.

Flow: EMS Hospital Supply Hub → Crew Sign-Off & Bio-Trash Pull → Hydrogen Peroxide Fog Sanitize → Sealed Med & O2 Cylinder Swap → Defibrillator & Pump Check → GPS Zone Post Ready → 911 / 112 City Zones

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Municipal Ambulance Fleet Bio-Wash & Narcotic StockSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. EMS Hospital Supply Hub → Crew Sign-Off & Bio-Trash Pull (739 s) → Hydrogen Peroxide Fog Sanitize (1,275 s) → Sealed Med & O2 Cylinder Swap (929 s) → Defibrillator & Pump Check (858 s) → GPS Zone Post Ready (596 s) → 911 / 112 City Zones.SUPPLIEREMS HospitalSupply HubI0.60 d1Crew Sign-Off &Bio-Trash PullC/T 739 sI1.21 d2Hydrogen PeroxideFog SanitizeC/T 1,275 sI0.71 d3Sealed Med & O2Cylinder SwapC/T 929 sI0.50 d4Defibrillator &Pump CheckC/T 858 sI0.29 d5GPS Zone PostReadyC/T 596 sI0.29 dCUSTOMER911 / 112 CityZones68 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Crew Sign-Off & Bio-Trash Pull739 s5 min97%98.4%1441 (0.60 d)103
2. Hydrogen Peroxide Fog Sanitize1,275 s10 min86%94.5%1082 (1.21 d)49
3. Sealed Med & O2 Cylinder Swap929 s8 min94%98.1%1048 (0.71 d)77
4. Defibrillator & Pump Check858 s8 min95%98.8%1034 (0.50 d)85
5. GPS Zone Post Ready596 s4 min98%99.4%720 (0.29 d)129

Key figures

Takt time
1,191 s
Lead time
3.66 d
Value-added time
4,397 s
Process cycle efficiency (PCE)
1.5%
Rolled throughput yield (RTY)
89.6%
Customer demand per day
68 units
Line capacity per day
49 units
Bottleneck
Hydrogen Peroxide Fog Sanitize

Reading the bottleneck

The bottleneck is "Hydrogen Peroxide Fog Sanitize": it can process 49 units per day against a demand of 68 units, so it falls short of demand by 27.9%. Once downtime and scrap are counted, its cycle time grows from 1,275 s to 1,569 s, against a takt of 1,191 s. The largest loss at this step is equipment downtime (uptime 86%), about 208 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Airports, Urban Transit & Postal Sorting: Airports, Urban Transit & Postal Sorting