Automated ANPR Airport Taxi Dispatch Pool Lot

Product family: Zero-Wait Curb Passenger Match.

Flow: City Licensed Taxis / EVs → Geofence Staging Lot Entry → EV Clean-Air Priority Lane → Terminal Curb Demand Trigger → Barrier Gate Dispatch Ticket → Curb Pax Load in 45s → Arriving Terminal Flyers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Automated ANPR Airport Taxi Dispatch Pool LotSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. City Licensed Taxis / EVs → Geofence Staging Lot Entry (27.9 s) → EV Clean-Air Priority Lane (48.0 s) → Terminal Curb Demand Trigger (35.1 s) → Barrier Gate Dispatch Ticket (32.4 s) → Curb Pax Load in 45s (22.5 s) → Arriving Terminal Flyers.SUPPLIERCity LicensedTaxis / EVsI0.60 d1Geofence StagingLot EntryC/T 27.9 sI1.20 d2EV Clean-AirPriority LaneC/T 48.0 sI0.70 d3Terminal CurbDemand TriggerC/T 35.1 sI0.50 d4Barrier GateDispatch TicketC/T 32.4 sI0.30 d5Curb Pax Load in45sC/T 22.5 sI0.30 dCUSTOMERArrivingTerminal Flyers1,800 / orders

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Geofence Staging Lot Entry27.9 s5 min97%98.4%3601,080 (0.60 d)2,720
2. EV Clean-Air Priority Lane48.0 s10 min86%94.5%2702,160 (1.20 d)1,304
3. Terminal Curb Demand Trigger35.1 s8 min94%98.1%2701,260 (0.70 d)2,044
4. Barrier Gate Dispatch Ticket32.4 s8 min95%98.8%270900 (0.50 d)2,254
5. Curb Pax Load in 45s22.5 s4 min98%99.4%180540 (0.30 d)3,403

Key figures

Takt time
45.0 s
Lead time
3.60 d
Value-added time
166 s
Process cycle efficiency (PCE)
0.057%
Rolled throughput yield (RTY)
89.6%
Customer demand per day
1,800 orders
Line capacity per day
1,304 orders
Bottleneck
EV Clean-Air Priority Lane

Reading the bottleneck

The bottleneck is "EV Clean-Air Priority Lane": it can process 1,304 orders per day against a demand of 1,800 orders, so it falls short of demand by 27.6%. Once downtime and scrap are counted, its cycle time grows from 48.0 s to 59.1 s, against a takt of 45.0 s. The largest loss at this step is equipment downtime (uptime 86%), about 7.8 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Airports, Urban Transit & Postal Sorting: Airports, Urban Transit & Postal Sorting