Complex Lithium NLGI-2 Bearing Grease Kettle

Product family: 400g Pull-Tab Grease Carts.

Flow: 12-HSA & LiOH Monohydrate → Pressurized Saponification → Flash Vacuum Cooling Mix → High-Press Homogenizer → Penetration & Drop-Point Lab → Automated 400g Cart & Cap → Mining & Bearing Distributors

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Complex Lithium NLGI-2 Bearing Grease KettleSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. 12-HSA & LiOH Monohydrate → Pressurized Saponification (2.5 s) → Flash Vacuum Cooling Mix (3.2 s) → High-Press Homogenizer (4.1 s) → Penetration & Drop-Point Lab (3.0 s) → Automated 400g Cart & Cap (2.2 s) → Mining & Bearing Distributors.SUPPLIER12-HSA & LiOHMonohydrateI1.40 d1PressurizedSaponificationC/T 2.5 sI1.60 d2Flash VacuumCooling MixC/T 3.2 sI2.00 d3High-PressHomogenizerC/T 4.1 sI1.10 d4Penetration &Drop-Point LabC/T 3.0 sI0.90 d5Automated 400gCart & CapC/T 2.2 sI1.50 dCUSTOMERMining &Bearing…14,000 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Pressurized Saponification2.5 s20 min95%99.1%21,00019,600 (1.40 d)20,034
2. Flash Vacuum Cooling Mix3.2 s45 min91%98.2%16,80022,400 (1.60 d)14,452
3. High-Press Homogenizer4.1 s18 min85%95.8%14,00028,000 (2.00 d)10,510
4. Penetration & Drop-Point Lab3.0 s30 min92%98.4%8,40015,400 (1.10 d)15,390
5. Automated 400g Cart & Cap2.2 s10 min97%99.5%5,60012,600 (0.90 d)23,032

Key figures

Takt time
3.9 s
Lead time
8.50 d
Value-added time
15.0 s
Process cycle efficiency (PCE)
0.003%
Rolled throughput yield (RTY)
91.3%
Customer demand per day
14,000 units
Line capacity per day
10,510 units
Bottleneck
High-Press Homogenizer

Reading the bottleneck

The bottleneck is "High-Press Homogenizer": it can process 10,510 units per day against a demand of 14,000 units, so it falls short of demand by 24.9%. Once downtime and scrap are counted, its cycle time grows from 4.1 s to 5.0 s, against a takt of 3.9 s. The largest loss at this step is equipment downtime (uptime 85%), about 0.7 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.