EFSA Food-Contact Bottle-to-Bottle rPET Pellet

Product family: Super-Cleaned SSP Resin.

Flow: Post-Consumer Baled Bottles → De-Bale, Hot Caustic Wash → Optical Flake Laser Sort → Twin-Screw Vacuum Extrude → 24h Nitrogen SSP Reactor → Intrinsic Viscosity IV & Benzene → Beverage Bottling Preform

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: EFSA Food-Contact Bottle-to-Bottle rPET PelletSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Post-Consumer Baled Bottles → De-Bale, Hot Caustic Wash (546 s) → Optical Flake Laser Sort (716 s) → Twin-Screw Vacuum Extrude (904 s) → 24h Nitrogen SSP Reactor (665 s) → Intrinsic Viscosity IV & Benzene (477 s) → Beverage Bottling Preform.SUPPLIERPost-ConsumerBaled BottlesI1.40 d1De-Bale, HotCaustic WashC/T 546 sI1.60 d2Optical FlakeLaser SortC/T 716 sI2.00 d3Twin-Screw VacuumExtrudeC/T 904 sI1.11 d424h Nitrogen SSPReactorC/T 665 sI0.91 d5IntrinsicViscosity IV &…C/T 477 sI1.51 dCUSTOMERBeverageBottling…95 / tonnes

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. De-Bale, Hot Caustic Wash546 s20 min95%99.1%143133 (1.40 d)138
2. Optical Flake Laser Sort716 s45 min91%98.2%114152 (1.60 d)98
3. Twin-Screw Vacuum Extrude904 s18 min85%95.8%95190 (2.00 d)72
4. 24h Nitrogen SSP Reactor665 s30 min92%98.4%57105 (1.11 d)106
5. Intrinsic Viscosity IV & Benzene477 s10 min97%99.5%3886 (0.91 d)161

Key figures

Takt time
853 s
Lead time
8.56 d
Value-added time
3,308 s
Process cycle efficiency (PCE)
0.48%
Rolled throughput yield (RTY)
91.3%
Customer demand per day
95 tonnes
Line capacity per day
72 tonnes
Bottleneck
Twin-Screw Vacuum Extrude

Reading the bottleneck

The bottleneck is "Twin-Screw Vacuum Extrude": it can process 72 tonnes per day against a demand of 95 tonnes, so it falls short of demand by 24.2%. Once downtime and scrap are counted, its cycle time grows from 904 s to 1,110 s, against a takt of 853 s. The largest loss at this step is equipment downtime (uptime 85%), about 160 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Lubricants, Adhesives & Petrochem: Lubricants, Adhesives & Petrochem