Hydrophilic Amino-Silicone Textile Softener

Product family: Micro-Emulsion Drum Batches.

Flow: Siloxane Cyclic Oligomers → Catalytic Siloxane Ring-Open → Non-Ionic Micro-Emulsification → Zeta Potential Stability Check → 5um Polish & Drum Fill → Padding Trial Shade Audit → Denim & Dyeing Mills

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Hydrophilic Amino-Silicone Textile SoftenerSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Siloxane Cyclic Oligomers → Catalytic Siloxane Ring-Open (1,234 s) → Non-Ionic Micro-Emulsification (1,620 s) → Zeta Potential Stability Check (2,044 s) → 5um Polish & Drum Fill (1,504 s) → Padding Trial Shade Audit (1,080 s) → Denim & Dyeing Mills.SUPPLIERSiloxane CyclicOligomersI1.39 d1CatalyticSiloxane…C/T 1,234 sI1.61 d2Non-IonicMicro-EmulsificationC/T 1,620 sI2.00 d3Zeta PotentialStability CheckC/T 2,044 sI1.11 d45um Polish & DrumFillC/T 1,504 sI0.89 d5Padding TrialShade AuditC/T 1,080 sI1.50 dCUSTOMERDenim & DyeingMills28 / tonnes

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Catalytic Siloxane Ring-Open1,234 s20 min95%99.1%4239 (1.39 d)41
2. Non-Ionic Micro-Emulsification1,620 s45 min91%98.2%3445 (1.61 d)29
3. Zeta Potential Stability Check2,044 s18 min85%95.8%2856 (2.00 d)21
4. 5um Polish & Drum Fill1,504 s30 min92%98.4%1731 (1.11 d)31
5. Padding Trial Shade Audit1,080 s10 min97%99.5%1125 (0.89 d)47

Key figures

Takt time
1,929 s
Lead time
8.64 d
Value-added time
7,482 s
Process cycle efficiency (PCE)
1.6%
Rolled throughput yield (RTY)
91.3%
Customer demand per day
28 tonnes
Line capacity per day
21 tonnes
Bottleneck
Zeta Potential Stability Check

Reading the bottleneck

The bottleneck is "Zeta Potential Stability Check": it can process 21 tonnes per day against a demand of 28 tonnes, so it falls short of demand by 24.7%. Once downtime and scrap are counted, its cycle time grows from 2,044 s to 2,510 s, against a takt of 1,929 s. The largest loss at this step is equipment downtime (uptime 85%), about 361 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Lubricants, Adhesives & Petrochem: Lubricants, Adhesives & Petrochem