Smart Building BACnet / KNX HVAC Commissioning

Product family: Zero-Fault Digital Twin Cx.

Flow: Building Automation Controllers → Edge IP Controller Field Mount → DALI Lighting & Damper Loop → Point-to-Point Graphics Check → Automated Functional Seq Test → Air Balancing & LEED Handover → Net-Zero Green Offices

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Smart Building BACnet / KNX HVAC CommissioningSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Building Automation Controllers → Edge IP Controller Field Mount (598 s) → DALI Lighting & Damper Loop (752 s) → Point-to-Point Graphics Check (1,032 s) → Automated Functional Seq Test (714 s) → Air Balancing & LEED Handover (501 s) → Net-Zero Green Offices.SUPPLIERBuildingAutomationControllersI1.00 d1Edge IPController Field…C/T 598 sI1.29 d2DALI Lighting &Damper LoopC/T 752 sI1.79 d3Point-to-PointGraphics CheckC/T 1,032 sI0.89 d4AutomatedFunctional Seq…C/T 714 sI0.50 d5Air Balancing &LEED HandoverC/T 501 sI0.61 dCUSTOMERNet-Zero GreenOffices28 / rooms

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Edge IP Controller Field Mount598 s10 min96%98.4%1128 (1.00 d)40
2. DALI Lighting & Damper Loop752 s12 min93%97.6%836 (1.29 d)30
3. Point-to-Point Graphics Check1,032 s20 min85%93.8%850 (1.79 d)18
4. Automated Functional Seq Test714 s8 min95%97.4%625 (0.89 d)32
5. Air Balancing & LEED Handover501 s5 min97%98.8%414 (0.50 d)48

Key figures

Takt time
964 s
Lead time
6.20 d
Value-added time
3,597 s
Process cycle efficiency (PCE)
2.1%
Rolled throughput yield (RTY)
86.7%
Customer demand per day
28 rooms
Line capacity per day
18 rooms
Bottleneck
Point-to-Point Graphics Check

Reading the bottleneck

The bottleneck is "Point-to-Point Graphics Check": it can process 18 rooms per day against a demand of 28 rooms, so it falls short of demand by 37.1%. Once downtime and scrap are counted, its cycle time grows from 1,032 s to 1,294 s, against a takt of 964 s. The largest loss at this step is equipment downtime (uptime 85%), about 182 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.