Food & Pharma Seamless Polyurethane Screed Floor

Product family: HACCP Thermal-Shock Floors.

Flow: Polyurethane Floor Resin Kits → Diamond Shot-Blast & Anchor → Cove Skirting Trowel Form → 6mm Thermal Trowel Pour → Spiked Roller De-Air & Quartz → 24-Hr Rapid Forklift Cure → Food & Beverage Plants

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Food & Pharma Seamless Polyurethane Screed FloorSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Polyurethane Floor Resin Kits → Diamond Shot-Blast & Anchor (698 s) → Cove Skirting Trowel Form (878 s) → 6mm Thermal Trowel Pour (1,204 s) → Spiked Roller De-Air & Quartz (833 s) → 24-Hr Rapid Forklift Cure (585 s) → Food & Beverage Plants.SUPPLIERPolyurethaneFloor ResinKitsI1.00 d1DiamondShot-Blast &…C/T 698 sI1.29 d2Cove SkirtingTrowel FormC/T 878 sI1.79 d36mm ThermalTrowel PourC/T 1,204 sI0.92 d4Spiked RollerDe-Air & QuartzC/T 833 sI0.50 d524-Hr RapidForklift CureC/T 585 sI0.58 dCUSTOMERFood & BeveragePlants24 / rooms

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Diamond Shot-Blast & Anchor698 s10 min96%98.4%1024 (1.00 d)35
2. Cove Skirting Trowel Form878 s12 min93%97.6%731 (1.29 d)25
3. 6mm Thermal Trowel Pour1,204 s20 min85%93.8%743 (1.79 d)15
4. Spiked Roller De-Air & Quartz833 s8 min95%97.4%522 (0.92 d)27
5. 24-Hr Rapid Forklift Cure585 s5 min97%98.8%412 (0.50 d)41

Key figures

Takt time
1,125 s
Lead time
6.24 d
Value-added time
4,198 s
Process cycle efficiency (PCE)
2.5%
Rolled throughput yield (RTY)
86.7%
Customer demand per day
24 rooms
Line capacity per day
15 rooms
Bottleneck
6mm Thermal Trowel Pour

Reading the bottleneck

The bottleneck is "6mm Thermal Trowel Pour": it can process 15 rooms per day against a demand of 24 rooms, so it falls short of demand by 36.9%. Once downtime and scrap are counted, its cycle time grows from 1,204 s to 1,510 s, against a takt of 1,125 s. The largest loss at this step is equipment downtime (uptime 85%), about 212 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of Commercial Building MEP & Fit-Out Trades: Commercial Building MEP & Fit-Out Trades