Automotive ASIL-D EV BMS Mainboard SMT

Product family: High-Voltage Sense Boards.

Flow: Automotive-Grade PCB Supplier → Vacuum Stencil & 3D SPI → Auto Dual-Gantry SMD → Nitrogen Reflow & AXI X-Ray → Press-Fit Iso-Conn & Gel Coat → HV Isolation Boundary Test → EV Battery Integrators

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Automotive ASIL-D EV BMS Mainboard SMTSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. Automotive-Grade PCB Supplier → Vacuum Stencil & 3D SPI (18.9 s) → Auto Dual-Gantry SMD (27.7 s) → Nitrogen Reflow & AXI X-Ray (36.1 s) → Press-Fit Iso-Conn & Gel Coat (26.3 s) → HV Isolation Boundary Test (23.0 s) → EV Battery Integrators.SUPPLIERAutomotive-GradePCB SupplierI1.20 d1Vacuum Stencil &3D SPIC/T 18.9 sI1.40 d2Auto Dual-GantrySMDC/T 27.7 sI1.80 d3Nitrogen Reflow &AXI X-RayC/T 36.1 sI1.00 d4Press-FitIso-Conn & Gel…C/T 26.3 sI0.80 d5HV IsolationBoundary TestC/T 23.0 sI1.20 dCUSTOMEREV BatteryIntegrators1,600 / boards

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Vacuum Stencil & 3D SPI18.9 s25 min95%98.6%1,2801,920 (1.20 d)2,583
2. Auto Dual-Gantry SMD27.7 s35 min91%97.4%1,2802,240 (1.40 d)1,644
3. Nitrogen Reflow & AXI X-Ray36.1 s45 min84%95.4%1,6002,880 (1.80 d)1,139
4. Press-Fit Iso-Conn & Gel Coat26.3 s18 min93%98.1%6401,600 (1.00 d)1,780
5. HV Isolation Boundary Test23.0 s15 min95%98.8%4001,280 (0.80 d)2,057

Key figures

Takt time
33.8 s
Lead time
7.40 d
Value-added time
132 s
Process cycle efficiency (PCE)
0.033%
Rolled throughput yield (RTY)
88.8%
Customer demand per day
1,600 boards
Line capacity per day
1,139 boards
Bottleneck
Nitrogen Reflow & AXI X-Ray

Reading the bottleneck

The bottleneck is "Nitrogen Reflow & AXI X-Ray": it can process 1,139 boards per day against a demand of 1,600 boards, so it falls short of demand by 28.8%. Once downtime and scrap are counted, its cycle time grows from 36.1 s to 45.0 s, against a takt of 33.8 s. The largest loss at this step is equipment downtime (uptime 84%), about 6.9 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of PCB SMT & Box-Build EMS: PCB SMT & Box-Build EMS