Modular DIN-Rail Industrial Safety PLC I/O

Product family: SIL-3 Analog/Digital Bricks.

Flow: DIN-Rail Housing Suppliers → Dual-Side SMT & AOI → DIN Spring-Cage Wave Solder → Robotic Housing Snap-Fit → CANopen / Profinet Flash → HIL Channel Fault Inject QC → Factory Automation Integrators

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Modular DIN-Rail Industrial Safety PLC I/OSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. DIN-Rail Housing Suppliers → Dual-Side SMT & AOI (15.9 s) → DIN Spring-Cage Wave Solder (23.3 s) → Robotic Housing Snap-Fit (30.4 s) → CANopen / Profinet Flash (22.2 s) → HIL Channel Fault Inject QC (19.3 s) → Factory Automation Integrators.SUPPLIERDIN-RailHousingSuppliersI1.20 d1Dual-Side SMT &AOIC/T 15.9 sI1.40 d2DIN Spring-CageWave SolderC/T 23.3 sI1.80 d3Robotic HousingSnap-FitC/T 30.4 sI1.00 d4CANopen /Profinet FlashC/T 22.2 sI0.80 d5HIL Channel FaultInject QCC/T 19.3 sI1.20 dCUSTOMERFactoryAutomation…1,900 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. Dual-Side SMT & AOI15.9 s25 min95%98.6%1,5202,280 (1.20 d)3,071
2. DIN Spring-Cage Wave Solder23.3 s35 min91%97.4%1,5202,660 (1.40 d)1,954
3. Robotic Housing Snap-Fit30.4 s45 min84%95.4%1,9003,420 (1.80 d)1,352
4. CANopen / Profinet Flash22.2 s18 min93%98.1%7601,900 (1.00 d)2,108
5. HIL Channel Fault Inject QC19.3 s15 min95%98.8%4751,520 (0.80 d)2,451

Key figures

Takt time
28.4 s
Lead time
7.40 d
Value-added time
111 s
Process cycle efficiency (PCE)
0.028%
Rolled throughput yield (RTY)
88.8%
Customer demand per day
1,900 units
Line capacity per day
1,352 units
Bottleneck
Robotic Housing Snap-Fit

Reading the bottleneck

The bottleneck is "Robotic Housing Snap-Fit": it can process 1,352 units per day against a demand of 1,900 units, so it falls short of demand by 28.8%. Once downtime and scrap are counted, its cycle time grows from 30.4 s to 37.9 s, against a takt of 28.4 s. The largest loss at this step is equipment downtime (uptime 84%), about 5.8 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.

Other scenarios in this family

More scenarios of PCB SMT & Box-Build EMS: PCB SMT & Box-Build EMS