Modular 1MW Online Double-Conversion UPS

Product family: 97.5% Eco-Mode Data Center UPS.

Flow: IGBT Stacks & Fan Trays → 2m Heavy Cabinet Frame Build → Backplane Busbar & Bypass → Hot-Swap Inverter Brick Test → CAN Sync Master Display Wire → 1MW Step-Load Battery Burn → Tier-IV Cloud Data Centers

Open this map in the free editor

No account needed. Change any value and the indicators update.

Value stream map

Value stream map: Modular 1MW Online Double-Conversion UPSSupplier on the left, customer on the right, process steps in between with their cycle time, and a stock triangle with days of stock before each step. IGBT Stacks & Fan Trays → 2m Heavy Cabinet Frame Build (3,060 s) → Backplane Busbar & Bypass (3,510 s) → Hot-Swap Inverter Brick Test (4,860 s) → CAN Sync Master Display Wire (3,600 s) → 1MW Step-Load Battery Burn (2,880 s) → Tier-IV Cloud Data Centers.SUPPLIERIGBT Stacks &Fan TraysI1.67 d12m Heavy CabinetFrame BuildC/T 3,060 sI1.50 d2Backplane Busbar& BypassC/T 3,510 sI2.00 d3Hot-Swap InverterBrick TestC/T 4,860 sI1.08 d4CAN Sync MasterDisplay WireC/T 3,600 sI0.83 d51MW Step-LoadBattery BurnC/T 2,880 sI1.42 dCUSTOMERTier-IV CloudData Centers12 / units

Process steps

StepCycle timeChangeoverUptimeYieldBatchStock beforeCapacity per day
1. 2m Heavy Cabinet Frame Build3,060 s25 min95%99.1%1220 (1.67 d)16
2. Backplane Busbar & Bypass3,510 s20 min93%98.4%718 (1.50 d)14
3. Hot-Swap Inverter Brick Test4,860 s18 min86%95.8%524 (2.00 d)9
4. CAN Sync Master Display Wire3,600 s12 min93%97.6%313 (1.08 d)13
5. 1MW Step-Load Battery Burn2,880 s10 min96%99.0%210 (0.83 d)17

Key figures

Takt time
4,500 s
Lead time
8.83 d
Value-added time
17,910 s
Process cycle efficiency (PCE)
3.8%
Rolled throughput yield (RTY)
90.3%
Customer demand per day
12 units
Line capacity per day
9 units
Bottleneck
Hot-Swap Inverter Brick Test

Reading the bottleneck

The bottleneck is "Hot-Swap Inverter Brick Test": it can process 9 units per day against a demand of 12 units, so it falls short of demand by 27.4%. Once downtime and scrap are counted, its cycle time grows from 4,860 s to 5,899 s, against a takt of 4,500 s. The largest loss at this step is equipment downtime (uptime 86%), about 791 s per unit. Reducing that loss is where the first improvement test belongs.

The figures on this page are illustrative starting values to be replaced with your own measurements. They are not industry benchmarks.